OUTDOOR B
BBQ G
GRILLS
Technical Data
6-2
GAS PRESSURE
Natural Gas Minimum
Liquid Propane Minimum
Natural Gas and Liquid Propane Maximum
Gas Supply Line Pressure
Liquid Propane Manifold Pressure, with Standard Orifice
14” WC
Natural Gas Manifold Pressure, with Standard Orifice
7” WC
11” WC
10” WC
5” WC
Description
BTU
Stamp No. Part No.
Valve, Burner Side
16,000
*49
720510
Orifice
800805
Valve, Burner Grill
16,000
*53
720510
Orifice
800806
Infrared Burner, Small
9,000
*55
715554
Orifice 800800
Infrared Burner, Large
9,000
*50
714555
Orifice 800048
Pilot Burner w/Orifice
720513
ORIFICE CHART
Natural Gas 5” WC
Description
BTU
Stamp No. Part No.
Valve, Burner Side
16,000
*56
720484
Orifice, 800807
Valve, Burner Grill
16,000
*63
720484
Orifice
800808
Infrared Burner, Small
9,000
*65
715554
Orifice
800804
Infrared Burner Large
9,000
*
64
714555
Orifice
800803
Pilot Burner w/Orifice
720511
Liquid Propane Gas 10” WC
For Units Installed Over 6,000 Ft. Contact the Factory for High Altitude Conversion Kit.
* Standard Orifice Size Supplied with Unit.
LP TANK RUNNING TIMES
BBQ Model #
BTU
Running Time
(hours)
BBQ36/BBQ36C 69,000
6-1/2
BBQ242/BBQ242C
80,000
5-1/2
BBQ48/BBQ48C
89,000
5
BBQ362/BBQ362C
101,000
4-1/2