General Information
2
Installation Information
5
Component Access & Removal
15
Troubleshooting Guide
19
Technical Data
27
Wiring Diagrams
28
subzero.com 800.222.7820
V Series Cooktop Ventilation
Service Manual
Страница 1: ...ral Information 2 Installation Information 5 Component Access Removal 15 Troubleshooting Guide 19 Technical Data 27 Wiring Diagrams 28 subzero com 800 222 7820 V Series Cooktop Ventilation Service Man...
Страница 2: ...er S p A Company TECHNICAL ASSISTANCE If you should have any questions regarding the appli ance and or this manual please contact Wolf Appliance Inc ATTN Service Department P O Box 44988 Madison WI 53...
Страница 3: ...ged and stored under unit serial num ber and or customer s name Please note that Wolf Appliance Inc requests that you have model and serial num ber available whenever contacting factory or parts distr...
Страница 4: ...ASH WITH MILD SOAP OR DETERGENT ONLY TO PROTECT FINISH WASH WITH MILD SOAP OR DETERGENT ONLY COMBINED RATING 2 6A 300W with BLOWER VENILATION 600CFM Internal Blower Unit 3 0A Maximum Recommended Remot...
Страница 5: ...Series Cooktop Hoods 1 6 825309 Revision A August 2014 Model Number Key Model ICB V W 36 G International Product Type Size Style Product V V Series Hoods Type W Wall Hood I Island Hood Size 30 36 42 a...
Страница 6: ...ducting Maximum amp draw of any Blower Motor used is 3 0 amps Notes For Electrical Placement and Ducting Installation Requirements see Page 8 It is possible to use 10 ducting but you would have to tra...
Страница 7: ...h Overall Height excluding chimney Minimum Height chimney contracted Maximum Height chimney extended Overall Depth Internal Blower s Inline Blower s Remote Blower s Duct Size 36 2 25 31 38 41 5 19 25...
Страница 8: ...dth Overall Height excluding chimney Minimum Height chimney contracted Maximum Height chimney extended Overall Depth Internal Blower s Inline Blower s Remote Blower s Duct Size 42 2 25 25 5 34 25 26 2...
Страница 9: ...th Overall Height excluding chimney Minimum Height chimney contracted Maximum Height chimney extended Overall Depth Internal Blower s Inline Blower s Remote Blower s Duct Size 36 6 0 34 75 45 38 22 30...
Страница 10: ...6G VW36G Overall Width Overall Height excluding chimney Minimum Height chimney contracted Maximum Height chimney extended Overall Depth Internal Blower s Inline Blower s External Blower s Duct Size 36...
Страница 11: ...20 00 20 00 23 63 23 63 2 25 2 25 0 00 to8 37 0 00 to8 37 VI45G VI45G Overall Width Overall Height excluding chimney Minimum Height chimney contracted Maximum Height chimney extended Overall Depth In...
Страница 12: ...NFPA70 Electrical supply for Wall Hoods and Island Hoods should be located in shaded area in Figure 2 From where Electrical Supply wires enter the hood area Allow a minimum of 12 inches wire for conn...
Страница 13: ...inches for even a short span reduces air flow for the entire duct run Duct run should not exceed 50 feet Equivalent Ducting Length See Figure 3 Internal and In Line blowers require a Roof or Wall Cap...
Страница 14: ...re is approximately 1 4 gap between the screw head and wall Note If wall framing is not available use of wall anchors is recommended 91 8 232 A 433 19 171 16 3 4 BOTTOM OF HOOD CEILING B Figure 5 Brac...
Страница 15: ...ort Frame Actual Template has a 6 diameter circle for ducting See Figure 7 a Use 1 1 4 drill to create a hole for electrical power supply b Place four mounting screws in ceiling in indi cated location...
Страница 16: ...ow When working on the Hood and components be careful when handling sheet metal parts There may be sharp edges present Chimney should only be secured at the locations provided for by the Hood Do Not c...
Страница 17: ...to 90 degrees Press Hinge Release Pin toward center of hood Disengage Filter Cover from the hinge See Figure 3 1 2 Slide Filter Cover to right and disengage pin from other hinge Hinge Release Pin Push...
Страница 18: ...cfm Internal Blower is mounted in Easy Cube portion of hood Once Filter Covers Black Hoods and Filters are removed Internal Blower can be extracted To Remove Internal Blower 1 Support Internal Blower...
Страница 19: ...See Figure 3 6 2 Release six tabs retaining Touch Control Assembly to Hood Figure 3 8 Power Board Assembly Figure 3 7 Wall Hood Easy Cube Side View Power Board Assembly Unit Electrical Box Screws to...
Страница 20: ...nt to component Note Before continuing please take note of the WARNINGS and CAUTIONS below TO AVOID ELECTRIC SHOCK POWER TO HOOD MUST BE DISCONNECTED WHEN PREPARING FOR A SPECIFIC TEST CARE SHOULD BE...
Страница 21: ...3 Page 5 Test Procedure 4 SYMPTOM Hood Lights and Blower do not energize No GFI Circuit Check house circuit is 115 VAC 15 amp dedi cated circuit Breaker is closed Bring circuit into specifi cation Clo...
Страница 22: ...ocking connector in Easy Cube Connector on Touch Pad If Ribbon Cable is seat ed correctly at all points and no voltage out of Power Board then the Power Board or Touch Control is bad Try replacing the...
Страница 23: ...Motor or Checks for External Inline Blower Motor Prior to these checks Check Voltage at J Box L1 to Ground 115 VAC N to Ground O VAC L1 to N 115 VAC If Lights are working likely this is a short or lo...
Страница 24: ...ter these checks if needed Blower Motor runs but not at all four Speeds Hood does not move enough Air Correct ducting installed Verify the duct run is the correct size including Wall Roof Cap is corre...
Страница 25: ...Pin 3 Voltage should be 0 VAC c Measure voltage from Pin 1 to Pin 3 Voltage should be 115 VAC 2 Testing Line Voltage at the Power Cable Power Cable plugs into the top of the Electrical Box on Easy Cu...
Страница 26: ...l Box Voltage should be 115 VAC See Figure 4 5 6 Testing Line Voltage to Transformer on Power Board On Power Board LUX1 is the voltage to Transformer a Disconnect LUX1 from Power Board and meas ure vo...
Страница 27: ...4 10 c Check for 115 VAC between Pin 1 and Pin 3 inside Easy Cube 12 Testing Blower Voltage at Blower Connection a Disconnect Internal Blower Cable connection from Internal Blower See Figure 4 11 b M...
Страница 28: ...ns to prior speed Boost increase air flow by approximately 20 Approximately 100 hour to activate Filter Alarm LED Assembly is S1000 LED Natural White 4000k Remote Control takes 2 AAA batteries Black H...
Страница 29: ...age goes through the Ribbon Cable Harness from the Power Board through the Easy Cube and connects to the Ribbon Cable from the Hood Body to provide power to the Touch Control A signal back to the Powe...
Страница 30: ...6 3 825309 Revision A August 2014 3 2 1 Blue Green Brown J Box 7 Pin Connector to Power Board Power Cable Electrical Connector 3 Pin Connector in Electrical Box Ground Blower Terminal Block Electrical...
Страница 31: ...r Harness Electrical Box 115 VAC is provided to terminals 1 and 2 Connect Blower Black wire to terminal A and White wire to terminal B For Internal Blower connector move Black wire to terminal A and W...
Страница 32: ...s V Series Cooktop Hoods 6 5 825309 Revision A August 2014 Power Board and Touch Control Power Board Touch Control in Hood Body Ribbon Cable Passes through Easy Cube Ribbon Cable From Hood Body connec...
Страница 33: ...and Transformer Additional LED Assemblies in Island Hoods LED Assembly with Two Pin Connector behind Light Support Electrical Box Connector passes through Electrical Box and connects in Easy Cube Con...
Страница 34: ...tor Remote Blower Motor Electrical Box J Box Power Cable Electrical Connector 3 Pin Connector Electrical Box Ground Blower Terminal Block Internal Blower Harness Touch Control Power Board Ribbon Cable...