Amongst  others  features,  an    important  one  is  that 
Incase one compressor is not capable of handling the 
load,  the  second  compressor  will  activate  and  both 
compressors  will cutout at the lowest set point. 

SZ-7552  is  two  compressor  controller  with  separate 
setpoints,  differentials  and  time  delays  for  each 
compressor. 

The controller features cycling of compressors so that 
there is no overload on one compressor. 

They  are  specifically  designed  for  air  conditioning 
applications wherein the compressor cuts off at setpoint 
and  is  restarted  at  a  temperature  of  setpoint  plus 
differential. 

Instruction for SZ-7552-P
General Description

1

2

INDEX

4

Parameter
Setting 

Press and hold
PRG(prg) key  
for 2 seconds. 
 

prg

Display will show ‘P2’ and flash.
To go to other parameters. Use 
UP / DOWN keys.

3

Set Point 

Function : To set the cutout point 
of the controller. 

Press & hold 
SET key for 2 
Seconds.

     R1 will flash along with respective 
setpoint1 for compressor 1. 
The setpoint1 value can now be 
changed by using the UP/DOWN 
keys. After achieving the desired 
value, press the set key and 
you will see “- - -” which confirms 
that the set point has been stored 
in memory. 

     R2 will flash along with 
respective set point 2 for 
compressor 2. In the similar 
manner use UP/DOWN key to 
set the desired value and press 
set key to confirm the settings. 

Display will change to set point 1 
and flash 

Set Point 1 & 2

Min  Max

Fac

O

1.0 C

Set Point 1 & 2

Min  Max

Fac

O

1 C

O

P2-1 C

rS = 0

rS = 1

rS = Resolution 

Set Parameter

P3

O

+1.0 C

P2

O

-1.0 C

O

P3+1 C

SZ-7552-P

www.pvrcontrols.com

INDIA

OPERATING

INSTRUCTIONS

Description

Parameter  Page 

Set Point1 and set point 2. 
To Set other parameters. 

Controller for heating or cooling.

Max. High Temp Limit. 
Min. Low Temp. Limit. 
Differential. 
Probe Calibration. 
Time Delay. 
To Start 2nd Comp. incase 1st Comp.
Min. Off time between two Comp. 
Avoid over loading of Comp. 
Keypad Lock.
Relay status on Probe Failure.
To set controller Resolution.
Factory set parameter.
End Programming.
Operating messages.
Technical data.