The information in this document is

 

subject

 

 to change in order to improve 

reliability , design or function without prior notice and does not represent

 

commitment on the part of the company. In no

 

event will the company be liable 

for direct, indirect, special, incidental or consequential damage arising out of 
the use or inability to use the product or documentation, even if advised of the 
possibility of such damages. No part of this manual may be reproduced or 
transmitted in any form or by any means without the prior written permission of 
the company.

 Notice

Disclaimer

 Warranty

This product is warranted against defects in materials and workmanship for a 
period of one   year from the date of purchase. During the warranty   period, 
product determined by us to be defective in form or function will be repaired or, 
at our option,

 

replaced at no charge. This warranty does not apply if the product 

has been damaged by accident,

 

abuse, and misuse or as a result of service or

 modification other than by the company. This warranty is in lieu of any other 
warranty expressed or implied. In no event shall the company be held liable for 
incidental or consequential damages, such as lost revenue or lost business 
opportunity arising from the purchase of this product.

INDIA

Ball Valves

Globe Valves 

Hand Valves

Flow Switches

Solenoid Valves

OUR OTHER PRODUCTS

Cold Room Controller

Chiller Controller

Two Compressors Controller

Heating Controller

Humidity Controller

Pressure Controller

R

00 / 11.08.16

This manual & its contents remain the sole property of PVR Controls, India and 
shall not be reproduced or distributed without authorization. Although great 
care has been taken in the preparations of this document, the company or its 
vendors  in  no  event  will  be  liable  for  direct,  indirect,  special,  incidental  or 
consequential damage arising out of the use or inability to use the product or 
documentation, even if advised of the possibility of such damages. No part of 
this manual may be reproduced or transmitted in any form or by any means 
without the prior written permission of the company. PVR Controls reserves the 
right to make and changes or improvements without prior notice.

NC-120A

Содержание NANOCHILL NC-120A

Страница 1: ...User Manual NANOCHILL NC 120A www pvrcontrols com RST 2 SET NANOCHILL ...

Страница 2: ...rameters u Auto Manual reset for HP LP and AFT The Subzero NANO CHILL NC 120 are controllers that integrates all the basic control functions required by a chiller A user friendly Lcd screen displays all parameters status and alarm messages u Range 30 0ºC to 50 0ºC u HP LP Compressor O L SPP Pump O L Auxiliary Fault Introduction Features Items included 01 NC 120A NC 120A 02 NO 1 2 3 4 5 QTY 1No 1No...

Страница 3: ...point To set Antifreeze differential To set Main Liquid probe calibration To set Antifreeze probe calibration To set Condenser probe calibration CHILLER SET TEMP To set other parameters CHILLER SET TEMP COMP TIME DELAY HIGH TEMP ALARM LOW TEMP ALARM AFT PROBE STATUS AFT SET TEMP AFT DIFFERENTIAL LIQ PROBE CAL AFT PROBE CAL COND PROBE CAL PROGRAM MODE SET MODE HT POWER ON DLY DESCRIPTION PARAMETER ...

Страница 4: ...tart delay Contd Parameter List Min MINIMUM Max MAXIMUM Fact Set FACTORY SETTING DEFAULT Use UP DOWN keys to set desired value parameter press the set key To change Comp Time Delay NC 120A SET MODE PROGRAM MODE INDEX 05 Once the SET key is pressed the control goes into the normal mode and displays the temperature SET EXIT UP DOWN SCROLL 19 To set customer name to be displayed at controller power O...

Страница 5: ...er is set to 0 50 0 C then once chiller temperature 0 goes above 50 0 C then controller will show Ht and alarm will be ON Range Min Max Fact Set Range Min Max Fact Set Range Min Max Fact Set AFT SET TEMP Use UP DOWN keys to set desired value EXAMPLE If this parameter is set to 5 0ºC controller will trip the compressor on Antifreeze fault if the AFT sensor goes below 5 0ºC To change AFT SET TEMP pa...

Страница 6: ... only when the AFT Temperature goes above 7 0ºC 5 0ºC 2 0ºC 1 0ºC 10 0ºC 2 0ºC Range Min Max Fact Set Range Min Max Fact Set Range Min Max Fact Set Sr No Parameter LCD Message Description of parameters and functions Parameter setting method Use UP DOWN keys to set desired value EXAMPLE Same as Main Probe Cal To change Cond Probe Cal parameter press the set key Range Min Max Fact Set 10Amp 10Amp 0A...

Страница 7: ...Set voltage level 230Vac 0Vac Controller will sense faults at 0 230Vac Controller will sense faults at 20 Range Min Max Disable Enable Disable FAULT IN STAND BY Function This decides whether controller should display faults in stand by mode or not To change Fault in Stand By parameter press the set key mode Note Eventhough the fault sensing is disabled in satnd by controller will display High temp...

Страница 8: ...e Description of parameters and functions Parameter setting method And if this delay is set to 10seconds then condenser will switch on 10 seconds before compressor Use UP DOWN keys to set desired value If condenser is running with compressor COND RUN LOGIC always on With Comp Condensor will switch on off with compressor Always On Condensor will remain Use UP DOWN keys to set desired value 26 Funct...

Страница 9: ...tions Parameter setting method 35 EWFS NORMAL DLY Function It sets normal delay for EWFS fault sensing This avoids false tripping due to water splashing 34 Range Min Max 0Sec 120Sec 10Sec EWFS STARTUP DLY Function It sets power on delay for EWFS fault sensing To change EWFS Startup Dly parameter press the set key Use UP DOWN keys to set desired value Fact Set 33 CONFIG AUX I P Function This config...

Страница 10: ...ocked to set parameter press the set key To change Keypad Lock To change Clear Fault Log parameter press the set key 39 40 Function To lock keypad Function To clear last fault history Range Min Max Fact Set Range Min Max Fact Set Use UP DOWN keys to set desired value Store Store fault history Example If this parameter is set to Clear then it will clear all previous faults saved in the memory Store...

Страница 11: ...sired value Customer can set service telephone number which will display at power ON 47 Function To set customer service number parameter press the set key To change Enter Your No SET EXIT UP DOWN SCROLL Once the SET key is pressed the control goes into the normal mode and displays the temperature 48 Function To end programming To end Program mode press set key 2 RST Press for 4 seconds to reset H...

Страница 12: ...Relay 5A 250Vac Current Input 0 to 20Amp 0 Resolution 0 1 C 0 0 Probe Tolerance 0 3 C AT 25 C 0 0 Storage Temp 20 C to 70 C non condensing 0 Accuracy 1 C Resolution 0 1Amp 0 0 Range 30 0 C to 50 0 C Technical Data 22 NC 120A NC 120A Suggested Wiring Diagram PHASE NEUTRAL 1 2 1 4 8 2 5 9 3 6 10 7 11 14 12 15 13 16 17 24 25 19 23 26 20 27 21 22 LIQUID AFT COND NEUTRAL COMP O L HP LP SPPR PUMP O L AU...

Страница 13: ...troller with a soft moist cloth Do not use abrasive detergents petrol alcohol or solvents Fixing and dimensions of panel models To fix the unit slide the side lock 1 through the guides 2 as per the position shown in the figure Move the side lock in the direction of the arrow it permits to move the fastener in the opposite direction of the arrow 3 Fit the screw in the side lock in direction of the ...

Страница 14: ...her than by the company This warranty is in lieu of any other warranty expressed or implied In no event shall the company be held liable for incidental or consequential damages such as lost revenue or lost business opportunity arising from the purchase of this product INDIA Ball Valves Globe Valves Hand Valves Flow Switches Solenoid Valves OUR OTHER PRODUCTS Cold Room Controller Chiller Controller...

Отзывы: