Sub-Zero ID-30CI Скачать руководство пользователя страница 4

Page 4

2-4

#7030768 - Revision B - May, 2015

Electronic Control Info.

INTEGRATED SERIES (DRAWERS)

INTEGRATED SERIES (DRAWERS)

MAIN CONTROL BOARD

(DOT DENOTES
PIN #1 LOCATION)

ST-1

ST-3

ST-4

ST-6

ST-5

ST-7

ST-10

ST-13

ST-11

ST-9

ST-8

ST-12

ST-2

Figure 2-2.  Control Board Layout

Figure 2-3.  Control Board Summary Table (ID-30C/I and ID-36C/I Summary Table Shown)

CONTROL BOARD LAYOUT AND SUMMARY TABLE

The electrical connection points on the control board are labeled alphanumerically.  These labels correspond with
the alphanumeric control board summary table, located on the wiring diagrams.  By referencing the summary table,
it is possible to identify which components are connected at which connection points on the control board.  Below is
a layout diagram of the control board, and a copy of a summary table.  (See Figures 2-2 and 2-3)

NOTE:  

All components on the control board are non-replaceable.  If a problem with the control board is identified,

the complete control board must be replaced.

120 VOLT CIRCUIT

LOW VOLTAGE CIRCUITS

LOW VOLTAGE CIRCUITS CONT.

THERMISTOR CIRCUITS 

ID-C CONTROL BOARD SUMMARY

CIRCUIT

DESCRIPTION

FUNCTION

COLOR

CIRCUIT

DESCRIPTION

POWER INTO BOARD

POWER FRE COMPRESSOR
UNUSED
POWER DEF HEATER

BLACK

PURPLE

--

BLUE

POWER IN (L1)

FRE COMPRESSOR
UNUSED
DEF HEATER

ICEMAKER
UNUSED
UNUSED
UNUSED
ICEMAKER WATER VALVE

POWER ICEMAKER
UNUSED
UNUSED
UNUSED
POWERS IM WATER VALVES

PINK

--
--
--

TAN/WHITE

LINE POWER SUPPLY
NEUTRAL
EARTH GROUND

POWER INTO BOARD
NEUTRAL INTO BOARD
GROUND

BLACK
WHITE

GREEN/YELLOW

ST1-1

ST1-2
ST1-3
ST1-4

FUNCTION

COLOR

DRAWER SWITCH INPUT

UNUSED
UNUSED
UNUSED

YELLOW/BLACK

--
--
--

DRAWER SWITCH

UNUSED
UNUSED
UNUSED

ST9-1

ST9-2
ST9-3
ST9-4

UNUSED

UNUSED
UNUSED
UNUSED

--

--
--
--

UNUSED

UNUSED
UNUSED
UNUSED

ST9-5

ST9-6
ST9-7
ST9-8

GROUND

BLACK/YELLOW

DOOR SWITCH GROUND

ST9-9

UNUSED

UNUSED
UNUSED
UIM POWER

--

--
--

RED/WHITE

UNUSED

UNUSED
UNUSED
UIM 12 V POWER

ST10-1

ST10-2
ST10-3
ST10-4

UIM CAN_H

UIM CAN_L
UIM RETURN

YELLOW/RED

YELLOW/WHITE

BROWN/WHITE

UIM CAN BUS

UIM CAN BUS
UIM GROUND RETURN

ST10-5

ST10-6
ST10-7

UNUSED

UNUSED
UNUSED
UNUSED

--

--
--
--

UNUSED

UNUSED
UNUSED
UNUSED

ST11-1

ST11-2
ST11-3
ST11-4

POWER OUT HALF BRIDGE 1

POWER OUT HALF BRIDGE 2
POWER OUT HALF BRIDGE 3

GRAY/WHITE

GRAY/RED

GRAY/BLACK

BAFFLE

BAFFLE
BAFFLE

ST11-5

ST11-6
ST11-7

POWER OUT HALF BRIDGE 4

GRAY/BROWN

BAFFLE

ST11-8

UNUSED

UNUSED
UNUSED

--

--
--

UNUSED

UNUSED
UNUSED

ST12-1

ST12-2
ST12-3

UNUSED

--

UNUSED

ST12-4

ST2-1

ST2-2
ST2-3

ST3-1

ST3-2
ST3-3
ST3-4
ST3-5

NEUTRAL

NEUTRAL INTO BOARD

WHITE

ST4-1

WATER VALVE INPUT

SENSES WATER VALVE ACTIVATION

TAN

ST4-2

NEUTRAL

NEUTRAL INTO BOARD

WHITE

ST4-3

DEF BI-METAL

SENSES WHEN DEF HEATER SHUTS OFF

GRAY/WHITE

ST4-4

UNUSED

UNUSED

--

ST4-5

UNUSED

UNUSED

--

ST4-6

UNUSED

UNUSED

--

ST7-1

UNUSED

UNUSED

--

ST7-2

UNUSED

UNUSED

--

ST7-3

UNUSED

UNUSED

--

ST7-4

EVAP FAN 12 VDC POWER

EVAP FAN POWER

RED

ST7-5

REF EVAP FAN

VAR. SPEED CONTROL OUT

YELLOW

ST7-6

REF EVAP FAN

TACH INPUT

BLUE

ST7-7

EVAP FAN GROUND RETURN

EVAP FAN RETURN

BLACK/RED

ST7-8

UNUSED

UNUSED

--

ST7-9

UNUSED

UNUSED

--

ST7-10

CONDENSER FAN

VAR. SPEED CONTROL OUT

YELLOW/ORANGE

ST7-11

CONDENSER FAN

TACH INPUT

BLUE/ORANGE

ST7-12

DRAWER LED

DRAWER LED POWER

RED/ORANGE

ST8-1

DRAWER LED

DRAWER LED PWM

YELLOW/ORANGE

ST8-2

DRAWER LED

DRAWER LED GROUND

BLACK/ORANGE

ST8-3

UNUSED

UNUSED

--

ST8-4

UNUSED

UNUSED

--

ST8-5

UNUSED

UNUSED

--

ST8-6

SENSES TEMPERATURE

SENSES TMEPERATURE
UNUSED

BLUE/ORANGE

BROWN

--

REF CABINET

REF CABINET
UNUSED

ST6-1

ST6-7
ST6-2

UNUSED

--

UNUSED

ST6-8

SENSES TEMPERATURE

SENSES TEMPERATURE
SENSES TEMPERATURE

BLUE

BROWN

BLUE/BLACK

FRE CABINET

FRE CABINET
FRE EVAPORATOR

ST6-3

ST6-9
ST6-4

SENSES TEMPERATURE

BROWN

FRE EVAPORATOR

ST6-10

SENSES TEMPERATURE

SENSES TEMPERATURE
UNUSED

BLUE/PURPLE

BROWN

--

CONDENSER

CONDENSER
UNUSED

ST6-5

ST6-11

ST6-6

UNUSED

--

UNUSED

ST6-12

Содержание ID-30CI

Страница 1: ...Controls Operation 11 subzero com 800 222 7820 Integrated Drawer Service Manual...

Страница 2: ...D Liquid Crystal Display A semi liquid substance sandwiched between glass in the control panel assembly The molecules of this semi liquid substance have no specific orientation However when electricit...

Страница 3: ...ST 10 ST 13 ST 11 ST 6 ST 6 1 2 3 4 5 6 7 8 9 10 1 1234567 2 4 6 8 10 12 1 3 5 7 9 11 LOWER DRAWER SWITCH BLACK ORANGE YLLW ORN RED ORN N O UPR DRWR LED LWR DRWR LED THERMISTOR REF CAB THERMISTOR FRE...

Страница 4: ...ROUND ST9 9 UNUSED UNUSED UNUSED UIM POWER RED WHITE UNUSED UNUSED UNUSED UIM 12 V POWER ST10 1 ST10 2 ST10 3 ST10 4 UIM CAN_H UIM CAN_L UIM RETURN YELLOW RED YELLOW WHITE BROWN WHITE UIM CAN BUS UIM...

Страница 5: ...t up To switch the unit on touch the screen and current internal temperature readings will appear on the UIM See Figure 2 5 power 70 70 Figure 2 6 Home Screen ID 30C I UIM Shown Touch Appropriate Temp...

Страница 6: ...witched on whenever the top drawer is opened the option screen will appear for 2 to 4 sec onds or from the home screen press the arrow icon below are the different option screens depending on the mode...

Страница 7: ...adjust control panel brightness and contrast Touch to adjust door drawer alarm volume and pitch Touch to adjust door drawer alarm duration Touch to enter Sabbath mode Touch to view troubleshooting an...

Страница 8: ...sired language Touch the lan guage desired See Figure 2 18 NOTE Touching the Arrow key wil step back one screen If the screen is not touched for 10 to 15 seconds the home screen will reappear Language...

Страница 9: ...e Display Choose the brightness and contrast screen 1 2 dark sun icon to view or change the brightness and or contrast of the LCD of the UIM Touch the appropriate slide bar s to adjust See Figure 2 21...

Страница 10: ...he home screen will reappear 60S Door Alarm Time Figure 2 23 Drawer Alarm Time Screen sixty seconds chosen Star K Sabbath Mode Screen Choose the Star K screen Star with K inside icon to enable the Sab...

Страница 11: ...ervice Options Screen Code Requested After the password is entered the Service Options screen appears and the options can be scrolled in a loop The options to choose from words that will show on scree...

Страница 12: ...ulty the refrigerator compressor defaults to 20 minutes ON 40 min utes OFF cycling EE appears at right in LCD the service icon flashes and the appropriate fault code is logged If the refrigerator evap...

Страница 13: ...Units Temperature signals from the freezer compartment thermistor are monitored by the microprocessor When the freezer compartment thermistor detects high offset temperature calling for cooling the fr...

Страница 14: ...ater With Adaptive Defrost the length of time the defrost heater stays on to open the defrost terminator bimetal is observed by the microprocessor This length of time is used to calculate the number o...

Страница 15: ...eezer 6 hours Refrigerator 4 hours five consecutive times a fault code is logged defrost is initiated and the service icon will flash If approximately twenty four 24 hours worth of 100 run periods occ...

Страница 16: ...33 34 35 36 37 38 39 40 42 43 44 45 46 50 55 56 60 65 66 70 71 72 73 74 75 Failures Open Short Closed Unstable Miswire Normal Temps Miswire Overheat Bad Ohms Too Warm Large Temp Differential Second De...

Страница 17: ...95 96 97 98 99 Failures No Communication Communications Timeout Partial Communications Bad Micro Communication Micro Initialization Display Failure Flow Too Slow No Flow Framing Errors Excessive Coll...