background image

Sturtevant Richmont

Global Reach. Local Support.

Sturtevant Richmont Div. of Ryeson Corp.

3203 N. Wolf Road  Franklin Park, IL  60131

Phones: 847/455-8677  800/877-1347

Fax: 847/455-0347

E-Mail: [email protected]

Web Site: www.srtorque.com

Operating Instructions

Torque Control Verifier 2.4 GHZ

S/R Part No. 10467

Manual P/N: 857269 Rev. B

Date: 9/1/09

This product is not RoHS compliant.

Содержание TCV

Страница 1: ...N Wolf Road Franklin Park IL 60131 Phones 847 455 8677 800 877 1347 Fax 847 455 0347 E Mail CustomerService srtorque com Web Site www srtorque com Operating Instructions Torque Control Verifier 2 4 GH...

Страница 2: ...f Contents Contents Page Chapter 1 Introduction 1 Chapter 2 Domestic Warnings USA 4 Chapter 3 TCV Installation 5 Chapter 4 Tool Communications 9 Chapter 5 Using Device Programmer Software to Program t...

Страница 3: ......

Страница 4: ...ply force after the click and overtorque the fastener 2 When the correct technique is used the torque wrench spends a certain amount of time in the clicked position When the wrench is used too quickly...

Страница 5: ...ic con trollers or other peripheral devices the acceptability or lack of acceptability of each use of the wrench 1 2 Component Nomenclature 1 Cabinet The Cabinet houses all of the electronic component...

Страница 6: ...ntry Module The Power Entry Module houses the Receptacle for the Power Cord the Voltage Selector and Fuse Holder and the Power Switch 9 Receptacle The Receptacle accepts the female end of the supplied...

Страница 7: ...e connects the TCV to the electric power source This is a standard pc type cable and any cable of this type with a rated capacity of 120 VAC and 10 Amperes may be used 18 TCV Software The TCV software...

Страница 8: ...ass B computing device pursuant to FCC Rules Operation with non approved equipment is likely to result in interference to radio and TV reception The user is cautioned that changes and modifications ma...

Страница 9: ...ounted but should still be accessible 3 3 Source Power CAUTION This unit is capable of being powered by 115 VAC or 230 VAC both 50 and 60Hz Before powering up the unit for the first time make sure the...

Страница 10: ...fuses are located on the sides of the voltage selector fuse holder as shown in the accompanying photograph 6 Use the Power Cord to bring electric power from the source to the TCV Check the Power Swit...

Страница 11: ...o program the TCV before the unit is placed in ser vice This software will work on machines using the Windows XP Professional operating system Close all programs not necessary to computer operation be...

Страница 12: ...t charge is installed in the tool before beginning the learning procedure Insufficient battery charge for tool communications can cause confus tion and difficulty 3 Insure that no other TCV unit is un...

Страница 13: ...associated with the TCV the Clearing the Tool Memory procedure must be performed and the wrench must then again be put through the Creating the TCV Unit and Tool Association procedure above When thes...

Страница 14: ...pter 2 Ensure that power to the TCV is enabled On 3 Start the Device programmer software 4 Insure that the serial port on the computer is selected in the Tools menu on the software usually this will b...

Страница 15: ...he total number of cycles since the unit was placed in service or last reset to zero To reset the count to zero type zero in the entry area 13 The RF Channel may be selected by typing in any number be...

Страница 16: ...f the window to send the settings to the TCV When the transmission is complete the software can be closed and the computer disconnect ed from the TCV Additional Information For additional information...

Отзывы: