NUMA ORGAN 2
by Studiologic®
22
Troubleshooting
Problem
Possible cause
Solution
Numa Organ 2 does not
turn on.
No power is supplied.
Defective power
cable. Fuse is blown
inside the Numa
Organ 2.
Please make sure that
power is available and
switched on. Check
the power cable and
the internal fuse and
replace it if needed,
with a fuse as specified
on page XX..
Numa Organ 2 cannot
be controlled via MIDI.
MIDI data are not
being sent on MIDI
channel 1, 2 or 3.
Please send MIDI data
only on MIDI channel
1, 2 and/or 3.
No sound is heard.
Dynamic TOUCH /
[MIDI] is activated.
All drawbars are
pushed all the way in.
Volume is set to 0.
Defective connecting
cable / headphone.
A sustain pedal is
connected to Expres-
sion pedal input.
Deactivate Dynamic
TOUCH / [MIDI].
Pull at least one draw-
bar down.
Set the Volume to a
higher level.
Change the cable /
headphone.
Unplug the sustain
pedal from Expression
pedal in.
Only one sound is
heard in split mode.
All drawbars of the
lower zone are
pushed all the way in.
Pull at least one draw-
bar down for the silent
zone.
No sound from the
audio input is heard.
Level of Audio In is
set to minimum.
External sound de-
vice is not playing.
Defective cable con-
nection.
Adjust Stereo Audio In
Level
.
Check if the exter-
nal sound device is
sending audio signal.
Change the connec-
tion cable.
The Sustain pedal just
changes the Rotary
speed from Brake to
fast, but not Slow to
Fast.
The Rotary wheel is
set to Brake.
Set the position of the
Rotary wheel to Fast
or Slow. Please also
refer to page 12.
Sustain pedal does not
hold notes if pressed.
Dynamic TOUCH /
[MIDI] is deactivated.
Activate Dynamic
TOUCH / [MIDI], if
you want to use the
foot switch as sustain
pedal.
Sustain pedal holds
notes if it is not pressed,
but cuts notes if
pressed.
The contact of the
attached sustain
pedal is closed at rest.
Plug in a sustain pedal
where contact is open
at rest.
Adjustments e.g. of the
drawbars cannot be
recorded with a
sequencer program.
Dynamic TOUCH /
[MIDI] is deactivated.
The MIDI Input of
the sequencer is not
set to MIDI channels
1, 2 and 3 or to “all
inputs”.
Activate Dynamic
TOUCH / [MIDI].
Set the input of the
sequencer to MIDI
channel 1, 2, 3 or to “all
inputs”.
Troubleshooting
Содержание numaorgan2
Страница 1: ...Version 1 2 Operation Manual Manuale di Istruzione IT EN...
Страница 2: ......
Страница 3: ...NUMA ORGAN 2 by Studiologic 3 ENGLISH Operation Manual EN...
Страница 24: ......
Страница 25: ...NUMA ORGAN 2 by Studiologic 25 Manuale di Istruzione ITALIANO IT...
Страница 46: ......
Страница 47: ...NUMA ORGAN 2 by Studiologic 47 Appendix Appendix...
Страница 50: ...RM 06 2014 v0...