background image

i n s t r u c t i o n   m a n u a l

12

i n s t r u c t i o n   m a n u a l

English

NUMA

 by Studiologic®

13

Edit

 Mode  Part 5

Patch Name

This page (Image 28) is for renaming patches. Select the letter 
in the patch name you want to change with the Function 
Keys  

and 

w

 . Then choose a New letter with the Virtual 

Dial. Function Key 

 (cap) switches between small and 

capital letters. When you´ve finished the entry, choose 

Yes

 

(

). Confirm the upcoming security query with 

Yes

 and 

that‘s it. 

Note

: No extra store command necessary.

System

Here you can adjust all common parameters to your personal 
needs (Image 29).

LCD Contrast

 controls the contrast of the display in a range 

from -64 up to +64.
The 

Dial Sensitivity

 (1-10) is for the sensitivity of the Virtual 

Dial 

¢ 

. Parameter 

Dial Velocity

 (1-20) controls the speed of 

the Virtual Dial 

¢ 

.

ATTENTION: Touching pad 

Reset

 

brings the whole system 

back to factory start. All your settings and patches are 
erased - irrevocably!!

Touching 

PC

 starts a USB connection between the NUMA 

keyboard and a computer. There are two different modes:

USB Connection - Midi (Image 30) 
Transferring MIDI Data from the PC to the MIDI port of 
the NUMA
USB Connection - VCom (Image 31) 
This enables a communication between NUMA and PC 
with the software „Interactive NUMA“. Possibilities range 
from backup/restore to editing patches and shapes in 
realtime. 
PC Monitor and Keyboard can be used instead of the 
NUMA display and capacitive keys.  

Restore

 

enables a restart under factory condition without 

erasing user patches and shapes (Image 29).

Touching 

Store

 

saves all your system changes to memory,  

including the patch that comes up when you turn the NUMA 
on. This is the patch you started the 

Edit

 Mode from (Image 29).

Image 29

Image 28

Image 31

Image 30

Содержание Numa nano

Страница 1: ...I n s t r u c t i o n M a n u a l...

Страница 2: ...swimming pool bathtub or wet basement If this device is moved from a cold place to a warm room condensation can occur inside the unit To avoid damage please allow the unit to reach room temperature b...

Страница 3: ...hem to 15 presets These customized curves are available to every patch then Due to the integrated USB connection the NUMA can com municate with a computer It offers two modes of operation With USB MID...

Страница 4: ...1 Choosing the operation of Control Jack 1 Control Jack 2 Choosing the operation of Control Jack 2 Store How to save changes and creating a new patch Patch Name How to edit the patch name System Disp...

Страница 5: ...In Edit Mode they select the sub pages Control Keys 1 4 activate the corresponding parameter above the pad For example Zone Reset Store No or Yes Touching both u vsimultaneously activates the YouPlay...

Страница 6: ...Factory Patches cannot be erased Zones On Off Control Keys u x can be used for direct access to Zone On Off The corresponding state is illustrated through an active on or cancelled off loudspeaker Im...

Страница 7: ...lume of all zones with the Virtual Dial If you want to change the volume of zone 4 only then you have to select it with pad x first The display now pictures Zone Volume and zone 4 gets activated Image...

Страница 8: ...lect und MSB Bank select Three sub pages Image 10 11 12 can be selected with pads 56and displayed in the top row Values are Off and 0 up to 127 Please check the manual of your external sound module to...

Страница 9: ...or changing the pitch for 2 octaves octave steps Selecting a sub page is handled via the pads Note Both parameters can be combined but the maximum change is 2 Octaves Play Mode This mode enables you t...

Страница 10: ...a control change command from 0 up to 127 The Polarity parameter defines the direction of the changes Pol for an upward change or Pol for a downward change Note Any changes will take place only after...

Страница 11: ...itch from positive to negative This makes it easy to use a closed switch as an open one On the page Type Jack Image 24 choose which type of switch you use Continuous Like a volume Pedal Open switch Op...

Страница 12: ...speed of the Virtual Dial ATTENTION Touching pad Reset ubrings the whole system back to factory start All your settings and patches are erased irrevocably Touching PC starts a USB connection between t...

Страница 13: ...and w now show the arrows for navigating in the display Image 35 The new letter itself is chosen with the Virtual Dial Press Yes u if you are ready with the label Pressing Yes again stores the shape...

Страница 14: ...E with Numa Nano OS version will not send inadvertently all Midi data parameters to the outputs 3 New OMNI MODE feature is only for the pedal programming section On pedal page and selecting OMNI you c...

Страница 15: ...evice is excluded FATAR srl Zona Ind le Squartabue 62019 Recanati MC Italy declares that this product complies with the European Directives This declaration becomes invalid by modification on the devi...

Страница 16: ......