background image

2

SAFETY INFOrMATION

REaD aLL CaUtIONS aND waRNINgS PRIOR tO OPERatE thIS EqUIPMENt.

INStRUCtION tO PREvENt INjURy OR DaMagE DUE tO ELECtRIC ShOCk, FIRE, MEChaNICaL haZaRDS aND

Uv RaDIatION haZaRDS.

WArNINg

!

•PROTECTION AGAINST FIRE

  1) this equipment is designed for use with the following lamps only: 

HTI 150W or HTI 152W (OSrAM).

      DO NOT USE LAMP NOT COMPATIbLE!

  2) Maintain minimum distance of 0.3 meter from walls or any other type of flammable surfaces.
  3) Maintain minimum distance to lighted objects of 1.0 meter.
  4) Replace fuses only with the specified type and rating.
  5) Do not install the spot close to heat sources. Do not lay the connection cable on the spot when it is warm.

•PROTECTION AGAINST ELECTRIC SHOCK

  1) this equipment must be earthed.
  2) Class I equipment. the power supply cord includes a protective earthing conductor as part of the cord. 
  3) Disconnect power before lamp replacement or servicing (service personnel).
  4) Do not install the spot outdoor, directly exposed to the rain or moisture.

•PROTECTION AGAINST MECHANICAL HAZARDS

  1) Use safety chain when fixing this equipment.
  2) hot lamp explosion hazard. Do not open the equipment for five minutes after switching off.
  3) Equipment surface may reach temperature up to 85°C. allow about five minutes before handling.
  4) Replace the lamp if it is damaged or thermally deformed and, in any case, do not exceed the lamp’s life.

•PROTECTION AGAINST UV RADIATION HAZARDS

  1) Do not start on this equipment without lamp enclosure or if the protection screens, or ultraviolet screens are damaged.
  2) the protection screens, the lenses, or the ultraviolet filters must be replaced if they are visibly damaged and their
         effectiveness has been reduced, for example, by cracks or deep scratches.
  3) Do not look directly at the lamp while lamp is on.

IMPOrTANTE

!

•PROTEZIONE CONTRO IL FUOCO

  1) questo apparecchio è progettato per funzionare esclusivamente con la lampada 

HTI 150W or HTI 152W (OSrAM).

      NON USArE ASSOLUTAMENTE LAMPADE NON COMPATIbILI!

  2) Mantenere la distanza minima di 0.3 metri da pareti ed altre superfici infiammabili.
  3) Mantenere la distanza minima di 1.0 metri dagli oggetti illuminati.
  4) Sostituire i fusibili solo con altri dello stesso tipo e valore.
  5) Non installare il faro vicino a fonti di calore. quando il faro è caldo non appoggiarci sopra i cavi di connessione.

•PROTEZIONE CONTRO SCOSSE ELETTRICHE

  1) questo apparecchio necessita di messa a terra.
  2) apparecchio di Classe I. Il conduttore di protezione deve far parte del cavo di alimentazione.
  3) Disconnettere l’alimentazione prima di sostituire la lampada o aprire l’apparecchio. (personale di servizio).
  4) Non installare il faro all’esterno, esposto alla pioggia o all’umidità.

•PROTEZIONE CONTRO RISCHI MECCANICI

  1) quando si installa il faro usare la catena di sicurezza.
  2) Per evitare rischi di esplosione, aprire l’ apparecchio solo dopo trascorsi 5 minuti dallo spegnimento della lampada.
  3) La temperatura dell’apparecchio può raggiungere 85°C. attendere circa 5 minuti prima di operare sul faro.
  4) Sostituire la lampada se è danneggiata o deformata a causa del calore e, comunque, non superare la durata prescritta.

•PROTEZIONE CONTRO RISCHI DA RADIAZIONE UV

  1) Non accendere l’apparecchio senza lo schermo protettivo o se le lenti ed i filtri per l’ultravioletto sono danneggiati.
  2) gli schermi di protezione, le lenti e i filtri ultravioletti, devono essere sostituiti se sono visibilmente danneggiati e se la loro 
        efficacia è stata ridotta, per esempio, da fessure o incisioni profonde.
  3) Non guardare direttamente la lampada quando questa è accesa.

0,5m

F

•PROTECTION AGAINST DANGEROUS MATTERS

at the end of its working life, the product must not be disposed of as urbamn waste. It must be taken to a special local 
authority differentiate waste collection centre or to a dealer providing this service. the wrong disposal must be cause 
of environment and people damages in the presence of possible dangerous matters. there are provided for sanctions 
to a unauthorized disposal of these products.

•PROTEZIONE CONTRO SOSTANZE PERICOLOSE                                

questo prodotto a fine vita è oggetto di raccolta separata, non gettare nei comuni cassonetti di rifiuti urbani, né 
tantomeno nell’ambiente. Può essere consegnato presso gli appositi centri di raccolta differenziata predisposti dalle 
amministrazioni comunali, oppure presso i rivenditori che forniscono questo servizio. Lo smaltimento errato può cau-
sare danni alle persone e all’ambiente per la possibile presenza di sostanze pericolose. Sono previste sanzioni in caso 
di smaltimento abusivo dei suddetti prodotti.

INFORMAZIONI DI SICUREZZA

LEggERE attENtaMENtE tUttI gLI avvERtIMENtI PRIMa DI COMPIERE qUaLUNqUE OPERaZIONE SU

qUEStO aPPaRECChIO.

IStRUZIONI PER PREvENIRE LESIONI O DaNNI DOvUtI aL FUOCO, aLLE SCOSSE ELEttRIChE,

aI RaggI ULtRavIOLEttI ED aI RISChI MECCaNICI.

0,5m

F

Содержание SHARK 150

Страница 1: ...User s and operator s manual for art 0602 Manuale d uso e dell operatore per art 0602...

Страница 2: ...ction Collegamento fonte di alimentazione pag 6 DMX signal connection Collegamento segnale DMX pag 6 Control panel Pannello di controllo pag 7 EXAMPLE connection DMX controller spot Esempio di collega...

Страница 3: ...di connessione PROTEZIONE CONTRO SCOSSE ELETTRICHE 1 Questo apparecchio necessita di messa a terra 2 Apparecchio di Classe I Il conduttore di protezione deve far parte del cavo di alimentazione 3 Disc...

Страница 4: ...k 150 C si inserisce elegantemente in ogni tipo di ambiente Un circuito elettronico moderno ed affidabile ne garantisce stabilit e sicurezza di funzionamento per lungo tempo Art 0602 SHARK 150 C Per o...

Страница 5: ...ite continuous positioning rainbow STROBE SHUTTER 0 5 to 15 flash sec strobe 256 steps CONTROL INPUT standard interface RS 485 opto coupled input protocol USITT DMX512 auto mode function with built in...

Страница 6: ...light is normally available after approximately 3 minutes After the lamp has been ignited in its cold state the filler components mer cury halides and rare earths vaporise one after another At the sam...

Страница 7: ...ne The terminator is a terminal resistor fitted at the end of the cable furthest from the transmitter The terminal resistor should have the same value as the impedance of the connection cable We sugge...

Страница 8: ...i quattro pulsanti per la programmazione ESC exit from menu and return to a previus menu level esce dal menu e torna ad un livello inferiore Down to go backward in the selected options scorrimento in...

Страница 9: ...8 CONTROL PANEL FUNCTIONS FUNZIONI DEL PANNELLO DI CONTROLLO...

Страница 10: ...9 DMX Listing Lista dei valori DMX STUDIODUE s r l str Poggino 100 01100 VITERBO ITALY tel 39 0761 352520 fax 39 0761 352653 http www studiodue com E Mail info studiodue com service studiodue com...

Страница 11: ...10 SCHEMATIC DIAGRAM SCHEMA ELETTRICO...

Страница 12: ...Rev Date Sheet of JP20 1 2 JP21 1 2 3 4 5 6 7 8 JP32 1 2 3 4 JP18 1 2 3 U25 1 2 3 G OUT V R66 JP16 1 2 3 4 JP28 1 2 3 4 5 6 7 JP15 1 2 3 4 5 6 7 8 9 10 C86 R98 JP29 1 2 3 JP33 1 2 3 C43 R100 JP25 1 2...

Страница 13: ...F1 C35 R12 R47 R60 C4 C14 C62 C48 R36 C21 C83 Z2 U1 74AC374 3 4 7 8 13 14 17 18 1 11 2 5 6 9 12 15 16 19 D0 D1 D2 D3 D4 D5 D6 D7 OE CLK Q0 Q1 Q2 Q3 Q4 Q5 Q6 Q7 R40 R38 R50 R3 U5 21 23 24 13 1 2 5 11...

Страница 14: ...13 NOTE...

Страница 15: ...9 0761 352520 fax 39 0761 352653 info studiodue com www studiodue com for technical info service studiodue com STUDIO DUE Far East LTD HK Unit 13 On 7th Floor Heng Ngai Jewelry Centre 4 Hok Yuen Stree...