STUDER INNOTEC
COMPACT
COMPACT
COMPACT
COMPACT
User manual
COMPACT V2.0 E
9
3.3.2 Protection cover for the terminals
connections
The protection is available in option (Order ref.
CFC-01) and avoid to do wrong hazardous
connection on the terminals 230Vac. It mounted
with strain relief clamps for the cable.
3.4 Connecting Plan / Front side
.
Caution:
Check battery
polarity (+/-) before connecting!
A wrong connection could
damage the system.
16A-250Vac
BATTERY
SOLAR
Remote
control
Temp.
Don't open before
disconnect line
and battery
N
AC Input
AC Output
L
Eq
u
ali
ze
T
ran
sf
er d
el
ay
Auxiliary Contact
PE
N
L
PE
Remote
Power
sharing
C-2324
Ubat:
Pnom: 2300 VA
Uin: 150 - 250 Vac
N ° :
Uout: 230 V/50 Hz
T y p :
22-32 Vdc
I Solar:
I Charge: 70A
30A max.
O
M
A
L
B
C
D E
F
G
H
J
K
N
A
B/-
Battery cable (already installed)
B
SOLAR +/-
Connecting terminal for Solar modules
C
Remote contr.
Connecting terminal for Remote Control RCC-01
D
Equalize
Slide switch for equalization of the Battery
E
Transfer delay
Slide switch for Transfer Delay
F
Temp.
Connecting terminal for Temperature sensor CT-35
G
Aux. Contact
Connecting terminal for Auxiliary Contact
H
AC Input
Connecting terminal for AC-input. Located directly above this
terminal is the automatic safety cut-out for this terminal.
J
ID Plate
Identification plate with Technical data and Serial number