Troubleshooting

8

Troubleshooting

WARNING

Risk of injury and poisoning due to hazardous or hot
media.

Use personal protective equipment when carrying out any
work on the

fi

tting.

Safely collect the media and dispose of it in accordance
with environmental regulations.

Consult with the manufacturer regarding faults which are not
identi

fi

ed in the following table, or which cannot be traced to

the indicated causes.

Error

Possible cause

Corrective action

Incorrect
Measurement value

Air bubbles in the transmitter

fl

uid

Check that the

fi

tting is suf

fi

ciently

fi

lled with transmitter

fl

uid, top it

up if necessary

(

5.3 Installing the

fi

tting, Page 7 ).

Medium in the
transmitter

fl

uid

Defective separation
diaphragm

Changing the separation diaphragm

(

7.2.2 Changing the

separation diaphragm, Page 10).

Medium is leaking

Defective seal

Check the seal at the connection to the pipeline and replace it if
necessary

(

5.4 Installing

fi

tting in pipe, Page 8 ).

Tab. 3

Troubleshooting

301 287

BA-2017.09.21 EN

MDM 902

11

Содержание Series MDM 902

Страница 1: ...N Print No 301 287 TR MA DE Rev001 ASV St bbe GmbH Co KG Hollwieser Stra e 5 32602 Vlotho Germany Phone 49 0 5733 799 0 Fax 49 0 5733 799 5000 E mail contact asv stuebbe de Internet www asv stuebbe co...

Страница 2: ...fitting 7 5 3 1 Fill the fitting 7 5 3 2 Installing and filling the pressure gauge 7 5 4 Installing fitting in pipe 8 5 4 2 Connection with solvent welding butt weld spigot ends 8 5 4 3 Connection wit...

Страница 3: ...other applicable documents especially all safety instructions and warnings 1 2 Other applicable documents To download Resistance lists Resistance of materials used to chemicals www asv stuebbe de pdf_...

Страница 4: ...ere the pump is operated Make personal protective equipment available Qualified personnel Make sure all personnel tasked with work on the fitting have read and understood this manual and all other app...

Страница 5: ...tting is mounted with the bottom section facing the pressurized pipe carrying the medium The pressure gauge is mounted on the upper part The separation diaphragm transmits the media pressure to the pr...

Страница 6: ...erial damage due to inappropriate storage Store the fitting properly 1 Make sure the storage room meets the following condi tions Dry Frost free Vibration free Not in direct sunlight Storage temperatu...

Страница 7: ...fitting Before installation in the pipeline the fitting must be filled and the pressure gauge must be filled and mounted Follow the section drawing for assembly 9 5 Sectional drawing Page 12 Use the...

Страница 8: ...y be performed by technicians who have been specially trained for the pipework in question NOTE Material damage due to contamination of the fitting Make sure no contamination reaches the fitting Flush...

Страница 9: ...e to medium spraying out Use personal protective equipment when carrying out any work on the fitting NOTE Damage to the separation diaphragm due to lack of trans mitter fluid Before commissioning make...

Страница 10: ...nal drawing Page 12 ASV St bbe recommends a contact adhesive such as Pat tex Kraftkleber to bond the bottom section to the upper part 1 Unscrew the pressure gauge 1 anti clockwise from the upper part...

Страница 11: ...dicated causes Error Possible cause Corrective action Incorrect Measurement value Air bubbles in the transmitter fluid Check that the fitting is sufficiently filled with transmitter fluid top it up if...

Страница 12: ...lysantine or Aral Antifreeze Demineralized water Tab 4 Transmitter fluid when used in a potable water area 9 4 Tightening torques Description Torque Pressure gauge hand tight maximal 15 Nm Upper part...

Отзывы: