Safety
The manufacturer accepts no liability for damage caused
by disregarding any of the documentation.
2.1
Intended use
•
Only use the pump with suitable media (
ĺ
resistance lists).
•
When using the pumps for solid particles, agree use in
advance with the manufacturer.
•
Do not use pump for combustible or explosive
À
uids.
•
Adhere to the operating limits and size-dependent mini-
mum
À
ow rates.
•
Avoid cavitation:
–
Open the suction-side
¿
tting and do not use it to regu-
late the
À
ow.
–
Do not open the pressure-side
¿
tting beyond the
agreed operating point.
•
Avoid overheating:
–
Do not operate the pump while the pressure-side
¿
tting
is closed.
•
Avoid damage to the motor:
–
Do not open the pressure-side
¿
tting beyond the
agreed operating point.
–
Note the maximum permissible number of times the
motor can be switched on per hour (
ĺ
manufacturer's
speci
¿
cations).
•
Only use the pump as part of large systems/tools.
•
Consult with the manufacturer regarding any other use of
the device.
Prevention of obvious misuse (examples)
•
Observe pump limits of use regarding temperature, pres-
sure,
À
ow and speed (
ĺ
data sheet).
•
The power consumption of the pump increases as the spe-
ci
¿
c gravity of the pumped
À
uid increases. Adhere to the
permissible speci
¿
c gravity in order to eliminate the pos-
sibility that the pump, coupling and motor become over-
loaded (
ĺ
data sheet).
A lower speci
¿
c gravity is permissible. Adapt the auxiliary
systems accordingly.
•
Pumps used with water as the pumped liquid must not be
used for foodstuffs or drinking water. Use for food or drink-
ing water only if speci
¿
ed in the data sheet.
•
The type of installation should be selected only in accor-
dance with these operating instructions. For example, the
following are not allowed:
–
Hanging base plate pumps in the pipe
–
Overhead installation
–
Installation in the immediate vicinity of extreme heat or
cold sources
–
Installation too close to a wall
2.2
General safety instructions
Observe the following regulations before carrying out any
work.
2.2.1
Product safety
The pump has been built according to state-of-the-art technol-
ogy and the recognized technical safety regulations. Never-
theless, operation of the pump can still put the life and health
of the user or third parties at risk or damage the pump or other
property.
•
Operate the pump only if it is in perfect technical condition
and use it only as intended, staying aware of safety and
risks, and in adherence to the instructions in this manual.
•
Keep this manual and all other applicable documents com-
plete, legible and accessible to personnel at all times.
•
Refrain from any procedures and actions that would pose
a risk to personnel or third parties.
•
In the event of any safety-relevant faults, shut down the
pump immediately and have the fault corrected by appro-
priate personnel.
•
In addition to the entire documentation for the product,
comply with statutory or other safety and accident-preven-
tion regulations and the applicable standards and guide-
lines in the country where the pump is operated.