Troubleshooting
8
Troubleshooting
WARNING
Risk of injury and poisoning due to hazardous media liq-
uids!
Use personal protective equipment when carrying out any
work on the device.
Additional troubleshooting
Error
Possible cause
Corrective action
Medium is leaking out of the
fl
ange
Pre-tension of the O-ring too small
Retighten union nut by hand.
Scale dirty or damaged
Clean scale.
Replace scale.
Measurements dif
fi
cult to read
Measuring tube dirty
Clean or replace measuring tube
Float jammed
Clean measuring tube and
fl
oat
Defective display
Float weight defective
Check weight of
fl
oat:
•
Ask for weight from manufacturer
•
If weight differs, remove device,
insert new
fl
oat and re-install device
No display (only for measurement sensor
ZE3000, ZE3075 or limit sensor)
Float installed incorrectly
Ensure that a
fl
oat with magnet is
used.
Tab. 4
Troubleshooting
8.1
Clean measuring tube and
fl
oat
System is empty.
System has been
fl
ushed.
System is depressurized.
System has cooled down.
System is secured against being switched back on again.
1. Unscrew both union nuts.
–
Secure
fl
oat (heavy) from falling.
2. Remove device from pipe.
3. Ensure that measuring tube and
fl
oat are clean and free of
foreign matter.
–
If necessary, replace with new device.
4. Ensure that the
fl
oat can move freely.
5. Install device
300 458
BA-2016.08.09 EN
DFM 165 – 350
11