background image

General Description

The SRC14 accurately controls the temperature of 
a cooling liquid between -20 to +30ºC. The cooled 
liquid is then circulated to an external device via the 
inlet and outlet nozzle. The SRC14 has a capacity of 
14 litres.

Safety Advice Before Use

•  Beware some cooling mediums are ignitable  
 

above ambient temperatures, do not use with  

 

hazardous materials or liquids.

•  Never move or carry the unit when in use or  
 

connected to the mains electricity supply.

•  Please take care not to touch the cooling  
 

elements under the air filter, as these can be  

 

sharp.

•  Do not place anything on top of the unit  
 

during operation 

Installation

Position your recirculating cooler on a firm level 
surface. A byproduct of the air cooled refrigeration 
unit is heat, unnecessary heat build up can lower 
the cooling performance of the unit. To avoid 
this please ensure the unit is located in a well 
ventilated area. The unit should not be exposed 
to direct sunlight, humidity, dust or vibration. For 
optimum performance the following clearance 
should be allowed: 20cm from both sides, 60cm 
above the unit and 40cm behind. Do not obstruct 
the front ventilation on either unit.

Care should be taken not to tilt the SRC14 by 
more than 45 degrees when moving. Ensure that 
the castors on the SRC14 are locked prior to use 
(only the front 2 castors have stoppers).

Operation

Connection of hoses:

Connect the 90º elbows to the nozzles then 
connect the elbow adapters including flow control 
valve (Fig. 2) Connect suitable tubing (ID 9mm) to 
each nozzle (inlet and outlet)

NOTE: Take care not to use excessive force 
connecting the hoses, use universal clips or similar 
to secure the tubing if necessary. Always consider 
the temperature and pressure requirements before 
selecting your tubing material. Use tubing of the 
minimum length required, excessively long tubing 
will reduce the efficiency of the unit.

Filling procedure:

When choosing your cooling medium you should 
take care that there is no risk of corrosion of internal 
parts, these include the following materials; copper, 
stainless steel, brass, PTFE, polyacetal resin, silicone 
rubber, polypropylene oxide and ethylene propylene 
rubber. Distilled water should also be avoided as it 
could dissolve metal substances in the circulation 
line. For operation below +7ºC it is recommended 
that ethylene glycol is used as your cooling medium.
Prior to filling the unit make sure that the drain 
stopper is in place. Pour 14 litres of your cooling 
medium into the circulation tank, or until the liquid 
level is approximately 2 cm from the top of the tank, 
take care not to overfill. Replace the circulation tank 
cover.

Operation

Connect the power lead to the IEC connector at the 
back of the unit. Make sure that the power switch 
and pump switch are in the off position on the 
control panel (Fig. 3) then connect the power cable 
to the mains supply. Turn the power switch on the 
main control panel to the on position. The display 
will show the current temperature of the cooling 
medium. The refrigeration unit will automatically 
start if the current temperature is 0.5ºC higher than 
the set temperature (the temperature is set to 20ºC 
before shipment). The refrigerator must be switched 
on manually using the switch on the control panel, 
once on, it will automatically cut in and out to 
control the temperature of the cooling medium.

Fig.2

Содержание SRC14

Страница 1: ...Recirculating Cooler SRC14 Instructions for use Version 2 0 ...

Страница 2: ...n provided may be impaired Electrical Installation THIS EQUIPMENT MUST BE EARTHED Before connection please ensure that the line supply corresponds to that shown on the rating plate This model requires a supply rated at 220 240V 50 Hz single phase Model Supply requirements Power SRC14 230V 50 Hz 1 1kW There is an IEC socket at the rear of the instrument for connection to the mains supply The unit i...

Страница 3: ...sive force connecting the hoses use universal clips or similar to secure the tubing if necessary Always consider the temperature and pressure requirements before selecting your tubing material Use tubing of the minimum length required excessively long tubing will reduce the efficiency of the unit Filling procedure When choosing your cooling medium you should take care that there is no risk of corr...

Страница 4: ... more than 5 seconds Pb will be displayed Using the up and down key to select the correct value as measured on the thermometer calibration can only be performed between 9 9ºC and 9 9ºC After setting the correct value press the set key for more than 5 seconds the display will return to the current measured temperature After operation Switch the circulation pump off then switch off the power switch ...

Страница 5: ...rformance and safety features designed into the instrument If in any doubt please contact the Technical Service Department of Bibby Scientific Ltd or the point of sale To open fusebox insert a small screwdriver into the slot and push downwards Drainage hose Fuse box AC outlet Drainage hose Fuse box AC outlet Bibby Scientific Ltd Stone Staffordshire ST15 0SA United Kingdom Tel 44 0 1785 812121 Fax ...

Страница 6: ...contact your local service representative Follow procedure to change fuse in the Maintenance and services section Contact local service representative Cooling power is poor Refrigeration unit does not work The ambient temperature exceeds 35ºC Exhaust is blocked Refrigeration air filter is blocked Contact local service representative Try to lower the ambient temperature Check necessary clearance ar...

Страница 7: ...fications We cannot be sure that other equipment used in its vicinity will meet these standards and so we cannot guarantee that interference will not occur in practice Where there is a possibility that injury damage or loss might occur if equipment malfunctions due to radio frequency interference or for general advice before use contact the Technical Department of Bibby Scientific Ltd ...

Страница 8: ...225 9243 Fax 609 589 2571 www bibby scientific com Bibby Scientific Italia Srl Via Alcide de Gasperi 56 20077 Riozzo di Cerro al Lambro Milano Italia Tel 39 0 2 98230679 Fax 39 0 2 98230211 e mail marketing bibby scientific it www bibby scientific it Bibby Scientific Asia Ltd Room 607 Yen Sheng Centre 64 Hoi Yuen Road Kwun Tong Kowloon Hong Kong Tel 852 3583 1581 Fax 852 3583 1580 e mail bibby bib...

Отзывы: