- 8 -
3 ELECTRICAL INSTALLATION / EARTHING
3.11
Regulations:
The electrical installation must be carried out in
accordance with the current local regulations by a qualified person.
3.12
Safety:
In the interests of electrical safety a 30 mA residual current
device (
R.C.D. not supplied
) should be installed in the supply circuit.
This may be part of a consumer unit or a separate unit.
3.13 Before starting work on the electrical supply ensure power supply is
isolated.
3.14
DO NOT
allow the supply cord to contact hot surfaces, including the
motor shell, pump body or pipework. The cord should be safely
routed and secured by cable clips.
3.15
Earthing:
This appliance must be earthed via the supply cord, which must be
correctly connected to the earth point located in the terminal box.
3.16
Connections:
The pump must be permanently connected to the fixed wiring
of the mains supply using the factory fitted supply cord, via a dedicated
double pole switched fused spur off the ring main.
3.17
Wiring of connection unit:
WARNING: This appliance must be earthed.
The wires in the mains lead (supply cord) are coloured in accordance with the
following code:
Green and Yellow: Earth
Blue: Neutral
Brown: Live
As the colours of the wires in the mains lead of this appliance may not
correspond with the coloured markings identifying the terminals in your
connection unit proceed as follows:
z
The wire which is coloured green and yellow must be connected to the
terminal in the connection unit which is marked with the letter E or by the
earth symbol:
or coloured green or green and yellow.
z
The wire which is coloured blue must be connected to the terminal which
is marked with the letter N or coloured black.
z
The wire which is coloured brown must be connected to the terminal
which is marked with the letter L or coloured red.