background image

- 15 -

NOTES

Содержание PH 45 TS S

Страница 1: ...Read this manual carefully before commencing installation This manual covers the following products suitable for 230 1 50 supply PH 35 TS Pt No 46496 PH 35 TS Pt No 46445 PH 45 TS Pt No 46504 PH 45 T...

Страница 2: ...ambient temperatures must not exceed the values given in the technical specifications STORAGE If this product is not to be installed immediately on receipt ensure that it is stored in a dry frost and...

Страница 3: ...d closed valve PH 35 TS 30 metres PH 45 TS 42 metres PH 35 ES 30 metres PH 45 ES 42 metres z z The motor casing can become very hot under normal operating conditions Care must be taken to ensure it ca...

Страница 4: ...rnal wiring all cable routing and securing details are carefully noted to ensure re assembly to the same factory pattern is always maintained z z If the supply cord is to be changed or is damaged it m...

Страница 5: ...ay vary slightly from the picture above Fig 1 IMPORTANT With the pump removed from its packaging check for any damage prior to installation If any damage is found contact Stuart Turner Ltd within 24 h...

Страница 6: ...on where the maximum ambient temperature should not exceed 40 o C continuous or 50 o C intermittent ES models only 1 16 DO NOT fit a pump if the hot water is heated via a method whereby the water temp...

Страница 7: ...ation 2 15 Water retention Site the pump in a location where in the unlikely event of a water leak any spillage is contained or routed to avoid electrics or areas sensitive to water damage 2 16 Pump p...

Страница 8: ...be permanently connected to the fixed wiring of the mains supply using the factory fitted supply cord via a dedicated double pole switched fused spur off the ring main 3 17 Wiring of connection unit W...

Страница 9: ...arefully noted to ensure re assembly to the same factory pattern is always maintained 3 21 If the supply cord is to be changed or damaged it must be replaced by a special cord available from Stuart Tu...

Страница 10: ...ves in the closed position Damage will occur The pump must be primed filled with water before starting 4 16 Flooded suction conditions Turn on the isolating valves a Loosen vent plug and allow an even...

Страница 11: ...metres Maximum flow 34 l min 44 l min Minimum static inlet pressure 0 05 bar 0 5 metres Maximum static inlet pressure 1 4 bar 14 metres Maximum working pressure 600 kPa 6 bar Maximum viscosity 50 sec...

Страница 12: ...e 3 0 bar 30 metres 4 2 bar 42 metres Performance 9 l min 2 0 bar 20 metres 3 2 bar 32 metres Performance 18 l min 1 2 bar 12 metres 2 3 bar 23 metres Maximum flow 32 l min 40 l min Minimum static inl...

Страница 13: ...ut no liquid Air locked Bleed pipework and pump to clear air No liquid supply Check the supply valves are turned on Check outlet not restricted or blocked Connections reversed Check liquid connections...

Страница 14: ...e value or operation of the pump Reasonable evidence must be supplied that the product has been purchased within the guarantee term prior to the date of claim such as proof of purchase or the pump ser...

Страница 15: ...15 NOTES...

Страница 16: ...00 3 3 BS EN 61000 4 2 BS EN 61000 4 3 BS EN 61000 4 4 BS EN 61000 4 5 BS EN 61000 4 6 BS EN 61000 4 11 EMF Directive 1999 519 EC BS EN 62233 RoHs Directive 2011 65 EU WEEE Directive 2012 19 EU IT IS...

Отзывы: