- 10 -

STEP 5 ELECTRICAL INSTALLATION

WARNINGS:

The electrical installation must be carried out in accordance with the 
current national electrical regulations and installed by a competent 
person.

In the interests of electrical safety a 30 mA residual current device 
(R.C.D.) should be installed in the supply circuit.  This may be part of 
a consumer unit or a separate unit.

Before starting work on the electrical supply ensure power supply is 
isolated. 

This appliance must be earthed.

The motor and wiring must not be exposed to water. 

Do not allow the supply cord to contact hot surfaces, including the 
motor shell, pump body or pipework.  The cord should be safely 
routed and secured by cable clips.

The motor fitted to this pump is suitable for a 230/1/50Hz supply.  It is thermally

protected by an integral auto resetting thermotrip for your safety and rated for the duty
listed in the technical specification section.

Electrical Connection

The motor is provided with a factory fitted supply cord.  This must be permanently

connected to the fixed wiring of the mains supply.  Means for disconnection must be
incorporated in the fixed wiring in accordance with the wiring rules.

A suitable method of connection would be via a double pole switched, fused connection

unit complying with BS 1363-4, protected with a fuse (see fuse section).

The connection unit should be mounted in an easily accessible position and should be

labelled if confusion is possible, to allow easy identification of the pump isolating switch.

Earthing

This appliance must be earthed via the supply cord, which must be correctly connected

to the earth point located in the terminal box.

Copper or metallic pipework must have supplementary earth bonding where the

continuity has been broken by flexible hoses or plastic components.  Adjacent suction and
delivery pipes should be fitted with earthing clamps to BS 951 and connected with
earthing wire size 4 mm² (Fig. 11).  A standard kit is available from Stuart Turner (Part No.
17044).

Certain installations may require additional earthing arrangements such as equipotential

bonding.  Reference should be made to the relevant regulations concerning this subject to
ensure compliance.

Diagram of
earth continuity
connections

Fig.11

Содержание monsoon extra

Страница 1: ...onsoon Extra range is designed for pressure boosting applications in vented stored hot or cold clean water systems where under gravity no flow is available Inlet pressures to the pump and ambient temp...

Страница 2: ...from pressure vessel thread Ensure that the fibre washer is present at the bottom of the fitting point Screw the pressure vessel clockwise until hand tight to achieve a water tight connection This dia...

Страница 3: ...upwards Typical pump locations are in an airing cupboard or inside a vanity unit with a small purpose built dry and ventilated enclosure The enclosure should have a minimum clearance of 80 mm 3 betwee...

Страница 4: ...ust also be within the maximum requirement of 8 metres for N1 3 and 13 metres for other models Hot Water Installations The preferred pump location is at floor level next to the hot water cylinder or a...

Страница 5: ...The pump must be free to vent to the supply tanks at all times Hot Water Installations If it is not possible to locate the pump in the preferred area due to site limitations and it is necessary to pos...

Страница 6: ...0 The pipework feeds to the storage tank should be of adequate size to ensure replenishment rate of tanks is sufficient to meet the needs of the pump Care should be taken in the design of pipework run...

Страница 7: ...mm pipework Most preferred Fig 7 Least preferred N O T R E C C N O T R E C C 45 Pipework Connections Connection between pump and system outlets This should run as far as possible in 22 mm copper tube...

Страница 8: ...ipe must be supported against collapse with the pipe manufacturers recommended support sleeve pipe insert c Appropriate plumbing fittings from the John Guest speedfit push in plumbing fitting range Ot...

Страница 9: ...o pump head and that hoses are kept as straight as possible Do not kink or twist the hose In the case of horizontal feeds use a 22 mm John Guest stem elbow not supplied Do not bend the hose more than...

Страница 10: ...connected to the fixed wiring of the mains supply Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules A suitable method of connection would be via a d...

Страница 11: ...The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red Wiring Diagrams The supply cord and internal wiring within the terminal box are ro...

Страница 12: ...re fitted with a supply cord to the following specification Monsoon Extra N1 3 bar HO5VV F3 G 0 75 mm 6 Amp rated cable Monsoon Extra N2 4 N2 9 N3 7 bar HO7RN F3 G 1 0 mm 10 Amp rated cable If the sup...

Страница 13: ...torage capacity is adequate to meet the demand Ensure the pump chamber is full of water before starting the pump Failure to do this could result in seal damage To ensure dry running does not occur the...

Страница 14: ...unlikely event of a water leak any spillage is contained or routed to avoid electrics or areas sensitive to water damage 1 No routine maintenance is required but provision should be made for easy acce...

Страница 15: ...for instructions on re starting pump 6 As water is heated scale deposits are released in areas of hard water usually south of a line between the Wash and Bristol Channel scale can cause the mechanica...

Страница 16: ...20 kPa 4 2 bar 40 C 65 C 4 C 1 l min approx 140 kPa 1 4 bar 89 kPa 0 89 bar 1 metre 10 metres 47 metres 600 kPa 6 0 bar 40 C 65 C 4 C 1 l min approx 140 kPa 1 4 bar 89 kPa 0 89 bar Dimensions Length m...

Страница 17: ...er Check tank volume is adequate Consult makers instructions Pump starts when outlets are off or Pump cycles hunts on off frequently Leak in system Low pre charge pressure in pressure vessel Debris un...

Страница 18: ...ondition for a period of 5 minutes 7 The pump will then re start and if the water starvation condition remains present the pump will then stop operation after a 1 minute period 8 After three consecuti...

Страница 19: ...ition Abide by the Water Supply Water Fittings Regulations 1999 Always install isolating valves to both suction and delivery pipe work Ensure earth continuity between suction and delivery pipes Always...

Страница 20: ...1 572655 or return pump with accessories removed pipes etc Proof of purchase should accompany the returned unit to avoid delay in action Stuart Turner Ltd Henley on Thames Oxfordshire RG9 2AD ENGLAND...

Отзывы: