Stuart Turner monsoon extra Скачать руководство пользователя страница 1

INDEX ............................................... Page No

Application  . . . . . . . . . . . . . . . . . . . . . . . . 1

Storage  . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Typical Installation  . . . . . . . . . . . . . . . . . . 2

Pre-Installation Assembly  . . . . . . . . . . . . 2

Pump Location . . . . . . . . . . . . . . . . . . . . . 3

Pipework Connections  . . . . . . . . . . . . . . . 5

Pump Connections  . . . . . . . . . . . . . . . . . 7

INDEX ............................................... Page No

Electrical Installation  . . . . . . . . . . . . . . . . 10

Commissioning  . . . . . . . . . . . . . . . . . . . . 12

Maintenance  . . . . . . . . . . . . . . . . . . . . . . 14

Technical Specification  . . . . . . . . . . . . . . 16

Noise  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Trouble Shooting Guide . . . . . . . . . . . . . . 17

Environment Protection  . . . . . . . . . . . . . . 19

Please leave this instruction booklet with the pump as it

contains maintenance and safety information.

Installation Instructions
For Monsoon Extra
Negative Single Duty Pump

Medium Pressure N1.3 bar

High Pressure  N2.4 bar

High Pressure N2.9 bar

High Pressure N3.7 bar

PRODUCT DESCRIPTION

Electric motor driven centrifugal pump complete with an automatic control system,

consisting of flow switch, pressure switch, pressure vessel and electronic control.

APPLICATION

The Single Negative Monsoon Extra range is designed for pressure boosting

applications in vented stored, hot or cold, clean water systems, where under gravity, no
flow is available.  Inlet pressures to the pump and ambient temperatures must not exceed
the values given in the technical specifications.

This pump set must not be used for any other application without the 
written consent of Stuart Turner Limited and in particular, must not be 
connected directly to the mains water supply.

This appliance is not intended for use by persons (including children) 
with reduced physical, sensory or mental capabilities, or lack of 
experience and knowledge, unless they have been given supervision 
or instruction concerning use of the appliance by a person responsible
for their safety.
Children should be supervised to ensure that they do not play with the
appliance.

STORAGE

If this product is not to be installed immediately on receipt, ensure that it is stored in a

dry, frost and vibration free location in its original packaging.

Содержание monsoon extra

Страница 1: ...onsoon Extra range is designed for pressure boosting applications in vented stored hot or cold clean water systems where under gravity no flow is available Inlet pressures to the pump and ambient temp...

Страница 2: ...from pressure vessel thread Ensure that the fibre washer is present at the bottom of the fitting point Screw the pressure vessel clockwise until hand tight to achieve a water tight connection This dia...

Страница 3: ...upwards Typical pump locations are in an airing cupboard or inside a vanity unit with a small purpose built dry and ventilated enclosure The enclosure should have a minimum clearance of 80 mm 3 betwee...

Страница 4: ...ust also be within the maximum requirement of 8 metres for N1 3 and 13 metres for other models Hot Water Installations The preferred pump location is at floor level next to the hot water cylinder or a...

Страница 5: ...The pump must be free to vent to the supply tanks at all times Hot Water Installations If it is not possible to locate the pump in the preferred area due to site limitations and it is necessary to pos...

Страница 6: ...0 The pipework feeds to the storage tank should be of adequate size to ensure replenishment rate of tanks is sufficient to meet the needs of the pump Care should be taken in the design of pipework run...

Страница 7: ...mm pipework Most preferred Fig 7 Least preferred N O T R E C C N O T R E C C 45 Pipework Connections Connection between pump and system outlets This should run as far as possible in 22 mm copper tube...

Страница 8: ...ipe must be supported against collapse with the pipe manufacturers recommended support sleeve pipe insert c Appropriate plumbing fittings from the John Guest speedfit push in plumbing fitting range Ot...

Страница 9: ...o pump head and that hoses are kept as straight as possible Do not kink or twist the hose In the case of horizontal feeds use a 22 mm John Guest stem elbow not supplied Do not bend the hose more than...

Страница 10: ...connected to the fixed wiring of the mains supply Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules A suitable method of connection would be via a d...

Страница 11: ...The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red Wiring Diagrams The supply cord and internal wiring within the terminal box are ro...

Страница 12: ...re fitted with a supply cord to the following specification Monsoon Extra N1 3 bar HO5VV F3 G 0 75 mm 6 Amp rated cable Monsoon Extra N2 4 N2 9 N3 7 bar HO7RN F3 G 1 0 mm 10 Amp rated cable If the sup...

Страница 13: ...torage capacity is adequate to meet the demand Ensure the pump chamber is full of water before starting the pump Failure to do this could result in seal damage To ensure dry running does not occur the...

Страница 14: ...unlikely event of a water leak any spillage is contained or routed to avoid electrics or areas sensitive to water damage 1 No routine maintenance is required but provision should be made for easy acce...

Страница 15: ...for instructions on re starting pump 6 As water is heated scale deposits are released in areas of hard water usually south of a line between the Wash and Bristol Channel scale can cause the mechanica...

Страница 16: ...20 kPa 4 2 bar 40 C 65 C 4 C 1 l min approx 140 kPa 1 4 bar 89 kPa 0 89 bar 1 metre 10 metres 47 metres 600 kPa 6 0 bar 40 C 65 C 4 C 1 l min approx 140 kPa 1 4 bar 89 kPa 0 89 bar Dimensions Length m...

Страница 17: ...er Check tank volume is adequate Consult makers instructions Pump starts when outlets are off or Pump cycles hunts on off frequently Leak in system Low pre charge pressure in pressure vessel Debris un...

Страница 18: ...ondition for a period of 5 minutes 7 The pump will then re start and if the water starvation condition remains present the pump will then stop operation after a 1 minute period 8 After three consecuti...

Страница 19: ...ition Abide by the Water Supply Water Fittings Regulations 1999 Always install isolating valves to both suction and delivery pipe work Ensure earth continuity between suction and delivery pipes Always...