8  TROUBLE SHOOTING GUIDE

Symptoms

Probable Cause

Recommended Action

Pump will not start.

Electrical supply.

Check power supply.
Check fuse (see fuse section).
Check circuit breaker is set.
Check wiring connections.

Pump Jammed.

If motor ‘Buzzes’ switch off power and contact Stuart Turner.

Damaged pressure switch.

Turn off power.
Release system water pressure.
Turn on power, pump should start.  If NOT contact Stuart 
Turner.

Recommended static inlet/outlet 
heads exceeded.

Re-position pump (see pump location section).

Internal motor thermotrip 
activated.

Wait for thermotrip to auto-reset and check that duty point and 
run time is within specification (see technical specification).

Reduced/intermittent flow.

Incorrect or no anti-aeration 
flange fitted

Check that the installation complies with installation 
instructions.

Incorrect pipe sizes.

Check for correct pipe sizing, see Page 5 - Section 2.19.

Blocked inlet filters.

Clean inlet filters (see maintenance section).

Air in system.

Run system on full hot for several minutes.  Check that vents 
are fitted as detailed in instructions.

Hot water temperature set too 
high.

Reduce cylinder stat setting to 60 

o

C max.

Blocked shower head spray 
plate

Clean in accordance with manufacturers instructions.

No hot water.

Air locked water feed.

Vent hot water pump of air.
Check cold feed to hot water cylinder.
Check water level in cold water tank and that all stopcocks 
and isolating valves are open.

Heat source not operating.

Check boiler is switched ‘on’.
Check cylinder thermostat.
Check immersion heater.
Check cylinder contains hot water.

All hot water has been used.

Check tank volume is adequate.

Faulty thermostatic mixer valve.

Consult makers instructions.

Pump runs on with outlets 
closed.

Leak in system.

Check tap washers, w/c valve washers, pipe joints.

Damaged reed switch, P.C.B or 
pressure switch.

If pump continues to run, this indicates a closed circuit in 
either the flow switch reed, pressure switch or P.C.B. in the 
terminal box.  Contact Stuart Turner.

Jammed flow switch.

Remove outlet hoses and check that flow switch sits in lowest 
position.  Check float for free movement.

or

Pump cycles (hunts) on/off 
frequently.

Low pressure in pressure 
vessel.

Check pressure in pressure vessel (see maintenance 
section).

Debris under non-return valve 
sealing face.

Run at full flow to try and flush away debris or remove, clean 
or replace non-return valve.

Flexible hose leaks

Not fitted correctly.

Check that the hose is pushed firmly onto the pump inlet/
outlet connections and pipework.

Damaged ‘O’-rings.

Check copper pipe ends are cleanly cut and deburred.

Содержание 46601

Страница 1: ...it contains important guarantee maintenance and safety information Read this manual carefully before commencing installation This manual covers the following products CE compliant product Monsoon Extr...

Страница 2: ...wledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user...

Страница 3: ...supplied must be fitted to allow easy pump service 28 mm copper outlet pipework discharge Short 28 mm copper pipe tails to connect between isolating valve and flexible pipes 28 mm isolating valve non...

Страница 4: ...esign of pipework runs to minimize the risk of air locks e g use drawn bends rather than 90o bends 1 18 DO NOT introduce solder flux to flexible hoses pumps or pump parts manufactured from plastic 1 1...

Страница 5: ...ure The pump must be sited in a location where the maximum ambient temperature does not exceed 40 o C 2 19 Pipework For optimum performance pipework use 28 mm dia 22 mm can be used but will result in...

Страница 6: ...cold water supply Must be a DEDICATED AIR FREE supply via a tank connector Do not connect to the mains Fig 2 Cold water Hot water Unvented hot water cylinder Static inlet pressure Min 1 m Max 10 m Sta...

Страница 7: ...d The hose end is made water tight with a sealing washer on assembly nip tight to 4 5 Nm for water tight seal Do not overtighten 3 12 Hose to pipework Hoses terminating in G 1 threaded connections are...

Страница 8: ...be safely routed and secured by cable clips 4 15 Supplementary Bonding The pressure set is factory fitted with a supplementary earthing wire to ensure continuity throughout the assembly Fig 3 It must...

Страница 9: ...d of this appliance may not correspond with the coloured markings identifying the terminals in your connection unit proceed as follows The wire which is coloured green and yellow must be connected to...

Страница 10: ...and routing system Re assemble to the same pattern For information on cable connection consult the wiring diagram and cable gland fitting instructions 4 25 Cable Gland Fitting Instructions To enable...

Страница 11: ...ined to help and advise you over the phone 5 COMMISSIONING SYSTEM FLUSHING PRIMING STARTING 5 11 System Flushing The pipework system should be flushed out prior to the pump being connected to ensure a...

Страница 12: ...n water supplies connect power supply and test 6 13 Pressure vessel The pressure vessel should be checked once every 6 months to have its air charge checked or replenished this should be carried out a...

Страница 13: ...particularly applies to guest bathrooms used infrequently 6 15 Cleaners Disinfectants and Descalents Acid based descalents and aggressive cleaning agents must not come into contact with the pump The...

Страница 14: ...sumption 775 Watts 1136 Watts Full load current 3 5 Amps 5 1 Amps Rating Continuous S1 Continuous S1 Max No Starts per hour 60 60 Mechanical Min inlet head 1 metres 1 metres Max inlet head 10 metres 1...

Страница 15: ...n in accordance with manufacturers instructions No hot water Air locked water feed Vent hot water pump of air Check cold feed to hot water cylinder Check water level in cold water tank and that all st...

Страница 16: ...nd if the water starvation condition remains present the pump will then stop operation after a 1 minute period 6 The pump will remain in the off condition for a period of 5 minutes 7 The pump will the...

Страница 17: ...l box lid ensuring no cables are trapped Re fit the four terminal box lid retaining screws tighten to 0 8 Nm 8 14 Environment Protection Your appliance contains valuable materials which can be recover...

Страница 18: ...ump rating label and the back page of the installation instructions 2 Your name address telephone e mail 3 The date of installation Within the guarantee period we will repair free of charge any defect...

Страница 19: ...ty to quickly locate an installer in their area Registration is free simply click on the register as an installer link on our homepage at www stuart turner co uk and complete a short form which will e...

Страница 20: ...OR DRIVEN PUMP AS SERIAL NUMBER BELOW COMPLIES WITH THE ESSENTIAL REQUIREMENTS OF THE ABOVE E E C DIRECTIVES RESPONSIBLE PERSON AND MANUFACTURER STUART TURNER LIMITED HENLEY ON THAMES OXFORDSHIRE RG9...

Отзывы: