![Stuart Turner 28474 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/stuart-turner/28474/28474_installation-instructions-manual_1386354007.webp)
- 7 -
Cont ...
SECTION 2 - CAPACITOR REPLACEMENT
The parts required to replace the capacitor are:
ITEM
QTY
ITEM
QTY
23
Screws, Self Tapping
(K40 x 16 mm)
4
26
Adhesive Foam Pad
1
24 Capacitor
1
•
CAPACITOR - USED ON MONSOON UNIVERSAL PUMPS
7 µf
- N1.5, N2.0, N3.0 bar Single
N1.5, N2.0 bar Twin
10 µf - N3.0 bar Twin
•
DISASSEMBLY
•
Isolate electrical supply before fitting replacement part.
•
Replacing the capacitor, should only be carried out by a competent
person.
•
The supply cord and internal wiring within the terminal box are routed
and secured to ensure compliance with the electrical standard
EN 60335-1. It is essential that prior to any disturbance of this internal
wiring, all cable routing and securing details are carefully noted to
ensure reassembly to the same factory pattern is always maintained.
Fig. 12
Capacitor
rating
24
26
23
Terminal box lid
Fig. 11