INITIAL OPERATING INSTRUCTIONS
•
Consult instruction manual for commissioning instructions.
•
Do not run pump dry. Allow the water to be pumped to enter the pump body thus ensuring
the seal is lubricated before switching the pump on. Failure to do this will damage the
seal.
•
Carefully check pump and pipework for leaks whilst pump running and stationary before
leaving the installation unattended.
•
REASSEMBLY
Reassembly is the reverse of the disassembly instructions with the new replacement parts
fitted as required.
Note: For correct installation the capacitor must be secured and positioned as detailed in
Figs. 19 & 20.
Secure PCB nuts to a torque of 1.5 Nm (item A).
Secure terminal box lid screws to a torque of 0.8 Nm (item 23).
IMPORTANT NOTE
: For correct pump rotation, ensure both blue wires are connected to the
linked capacitor terminals as shown.