PRINCIPLE OF OPERATION
SMD-300 principle of operation is based on eddy current
pulses analysis.
That current, known as Foucault currents, are originated in
metallic items from the outside pulse magnetic field.
Pulse magnetic field is formed by two transmitting coils housed
in a round Sensor body. Foucault currents are arisen in a part of
the metallic body that is closer to the sensor and is under the
influence of the coils.
Foucault currents magnetic field is captured by receiving coil
of the sensor and processed by build-in
P.
Dedicated algorithm is used for this purpose.
The analysis results are displayed on a built-in LCD in a digital
or graphic mode on operator‟s preference.
Corresponding audio signal can be heard in the headphones as
well. The tone and loudness of it are adequate to the signal
level received.
SDM-300 operation is available by means of Control unit with
indication panel. All operational modes and the data obtained
are displayed on a build-in LCD.