Removing drums from pallets: 

• 

Pump the hydraulic handle to raise the drum to the desired height. 

• 

Remove drum from the pallet by gently pulling the depalletiser away. 

• 

When clear of the pallet and transporting the drum, keep the drum as low to 

the ground as is practical. 

• 

To place the drum down, simply turn the control lever anticlockwise locates 

on the top of the lifter. The rate at which the drum lowers is controlled by the 

amount that the lever is pulled.  

• 

Once the drum is placed on the floor (or another pallet), continue to lower 

the rack until the catch goes slack, the operator can then reach forward and 
manually remove the hook from the drum. 

• 

If the catch is lowered too much it is not possible to unhook the catch, in this 

instance raise the rack slightly by pumping the handle, the catch will go slack 
ready for unhooking. 

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание DTP05

Страница 1: ...Operating Instructions DTP05 Ex Corner Drum Depalletiser E mail sales sts trolleys co uk Tel 44 0 1736 851050 Fax 44 0 1736 851023...

Страница 2: ...ected at regular intervals decided by the operator s company for signs of damage or defects 10 The unit must be inspected at least annually or after any unusual event by a suitably competent person 11...

Страница 3: ...f the drum Push the unit forward so the top catch engages the drum Lower the rack slowly using the lowering lever ensuring the top hook engages over the top lip of the drum and that the bottom toggle...

Страница 4: ...rum as low to the ground as is practical To place the drum down simply turn the control lever anticlockwise locates on the top of the lifter The rate at which the drum lowers is controlled by the amou...

Страница 5: ...ch Changing the hole that the top catch is located in increases the reach by a further 10mm by each hole placement The top hook must always be placed in the shortest possible position The following ex...

Страница 6: ...he wheels are clean free from debris Hydraulic Operations Test hydraulic lift and lower function for correct operation Check hydraulic oil level via sight glass top up if below half sight glass Inspec...

Страница 7: ...batteries fuels and electronic and electrical systems must be observed Maintenance Any maintenance needs to be carried out by a competent individual The unit is designed to be maintenance free Before...