StrongLink SL060
http://www.stronglink-rfid.com
8
Table 2
Status
Description
0x00
Operation successes
0x01
NFC connect fails
0x0A
Operation fails
0x0B
Command is not supported
0x0C
Parameter is error
0x0D
No cards
0x0E
RF base station is damaged
0x14
Searching card fails
0x15
Reset card fails
0x16
Verifying key fails
0x17
Reading fails
0x18
Writing fails
4-4. Command List
4-4-1 System Function Command
4-4-1-1. Set baud rate
0xAA
0xBB
Len
DeviceID
0x01
0x01
Data
Checksum
Data: 0x00: BaudRate = 4800
0x01: BaudRate = 9600(default)
0x02: BaudRate = 14400
0x03: BaudRate = 19200
0x04: BaudRate = 28800
0x05: BaudRate = 38400
0x06: BaudRate = 57600
0x07: BaudRate = 115200
After changing the BaudRate, further communication must be set as the new BaudRate.
Response:
0xAA
0xBB
Len
DeviceID
0x01
0x01
Status
Checksum
Status: 0x00:
Operation succeed
0x0C:
Parameter error
4-4-1-2. Initialize the Device ID
0xAA
0xBB
Len
DeviceID
0x02
0x01
Data
Checksum
Data: 2 bytes device ID
Response:
0xAA
0xBB
Len
DeviceID
0x02
0x01
Status
Checksum
Status: 0x00:
Operation succeed
Remark:
SL060 only response to the command that Device ID is in accord with itself,
and broadcast command that DeviceID equals to 0x0000
4-4-1-3. Get device ID
0xAA
0xBB
Len
DeviceID
0x03
0x01 Checksum
Response: