![Strongarm 402A Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/strongarm/402a/402a_operating-instructions-manual_1385333003.webp)
No.
Description
Qty
1
Air Pump
1
2
Oil Dipstick
1
3
Adaptor 3/8" to 1/4" NPT
1
4
Operating Instructions
1
Remove shipping screw located on the top side of the cover. Replace shipping screw with the
supplied oil dipstick. Do not use a wrench or over tighten when installing the dipstick. Please
keep the shipping screw if needed for shipping or transport.
The pump is filled with high quality hydraulic oil at the factory. Prior to operation check that the
hydraulic fluid level is at the correct fluid level. If you need to add fluid unscrew the dipstick and
use a small funnel to fill. Use only high quality hydraulic fluid. Use of any other fluid will void
warranty and damage the pump. Never use brake fluid, transmisstion fluid, motor oil etc.
CONTENTS
!
ASSEMBLY
!