•  When using various shop equipment, basic safety precautions should always be followed.
•  Keep work area clean and free from debris.
•  Keep children away from work area and shop equipment. Keep hands and feet away from  

loading area.

•  Study, understand, and follow all instructions before operating this device.
•  Do not exceed rated capacity.
•  Do not operate the pump separately without connecting with ram.
•  Use only on a hard level surface.
•  Use clean, moisture free, and regulated compressed air. Do not use oxygen, carbon dioxide, 

combustable gases or bottled gas as a power source.

•  DO NOT attempt to operate the pump by standing on the treadle. Use only light foot pressure 

to operate the pump mechanism.

•  Never attempt to disconnect hydraulic connections under pressure. Release all line pressure 

before disconnecting hoses. 

•  DO NOT adjust factory set Safety Valve or Overload Valve. Valve should only be set or reset by 

qualified technician.

•  No alterations shall be made to this product.
•  Failure to heed these warnings may result in personal injury and/or property damage.

!

WARNING!

INSPECTION

!

The use of shop equipment is subject to certain hazards that cannot be prevented by mechanical 
means, but only by exercise of intelligence, care, and common sense. It is therefore essential 
to have personnel involved in the use and operation of equipment who are careful, competent, 
trained, and qualified in the safe operation of this equipment and its proper use. Examples of 
hazards are dropping, tipping, or slipping of parts/components caused primarily by improperly 
securing loads, overloading, off-centered loads, use on other than hard level surfaces, and using 
equipment for a purpose for which it was not designed.

The owner and / or operator shall study and understand the product and safety instructions before 
operating this equipment. Safety information shall be emphasized and understood. If the operator 
is not fluent in English, the product and safety instructions shall be read to and discussed with the 
operator in the operator’s native language by the purchaser / owner or his designee, making sure 
that the operator comprehends their contents. A copy of these instructions / warnings shall be 
retained for future reference.

Visual inspection shall be made before each use of this equipment, checking for abnormal 
conditions, such as cracked welds, leaks, damaged, loose or missing parts. This equipment shall 
be removed immediately from service if it is believed to have been subjected to an abnormal 
or shock load, the equipment shall be inspected by a qualified repair facility. Owners and / or 
operators should be aware that repair of this equipment may require specialized knowledge and 
facilities. It is recommended that this equipment be inspected annually by a qualified repair facility. 
Defective parts, decals, safety labels or signs should be replaced with STRONGARM specified parts.

WARNING!

!

2

Содержание 402A

Страница 1: ...rating procedures safety warnings and maintenance requirements Failure to do so could cause an accident resulting in serious or fatal injury and or personal property damage www strongarminc com M13 SA030215 10 000 PSI 54 oz Air Hydraulic Foot Pump Heavy Duty Operating Instructions PROD NO 030215 MOD NO 402A ...

Страница 2: ...careful competent trained and qualified in the safe operation of this equipment and its proper use Examples of hazards are dropping tipping or slipping of parts components caused primarily by improperly securing loads overloading off centered loads use on other than hard level surfaces and using equipment for a purpose for which it was not designed The owner and or operator shall study and underst...

Страница 3: ...stick Please keep the shipping screw if needed for shipping or transport The pump is filled with high quality hydraulic oil at the factory Prior to operation check that the hydraulic fluid level is at the correct fluid level If you need to add fluid unscrew the dipstick and use a small funnel to fill Use only high quality hydraulic fluid Use of any other fluid will void warranty and damage the pum...

Страница 4: ... air nipple not included to the air input port FIG 4 Tighten the air nipple but do not overtighten Connect air source to the hose conector Ensure that air source can dedicate 9 cfm air supply Use a good quality 3 8 air line hose Always secure threaded port connections with high grade pipe thread sealant When using the pump always use on a flat level surface If the pump needs to be fixed to a level...

Страница 5: ... and not to reach the clasped position Fig 5 Fig 6 Priming the Pump If the pump doesn t work properly at first it may have air in the hydraulic system if this happens you will need to bleed the system 1 Place pump on flat surface and depress the treadle RELEASE to clasp position in order to ensure the oil back to reservoir 2 Check the oil level Fill the pump with high quality hydraulic oil if nece...

Страница 6: ...evel Check oil level and top up Pump fails to reach maximum pressure Insufficient air pressure Check air supply must have 100 120 PSI Relief valve incorrectly set Contact the supplier Oil leak in the main hydraulic circuit Check the circuit for leaks and repair as necessary Pump delivers pressurized oil but load is not lifted Oil circulation fault Check if pipelines are obstructed or if cylinder i...

Страница 7: ... 34 Piston Cap 1 35 Lock Washer 3 36 Screw 3 37 Small Piston Circle 1 38 Air Cylinder 1 39 Air Cylinder Cap 1 40 Lock Washer 4 41 Screw 4 42 O Ring 2 43 Spring 1 44 Base For Steel Ball 1 NO DESCRIPTION QTY 45 Steel Ball 1 46 Valve Core 1 47 O Ring 3 48 Washer 3 49 Base For Release Valve 1 50 Valve Pin 1 51 Steel Ball 1 52 Spring 1 53 Valve 1 54 Seal Washer 1 55 Cover 1 56 Ruler 1 57 Rubber Pad 6 5...