Страница 1: ...rating procedures safety warnings and maintenance requirements Failure to do so could cause an accident resulting in serious or fatal injury and or personal property damage www strongarminc com M13 SA030215 10 000 PSI 54 oz Air Hydraulic Foot Pump Heavy Duty Operating Instructions PROD NO 030215 MOD NO 402A ...

Страница 2: ...careful competent trained and qualified in the safe operation of this equipment and its proper use Examples of hazards are dropping tipping or slipping of parts components caused primarily by improperly securing loads overloading off centered loads use on other than hard level surfaces and using equipment for a purpose for which it was not designed The owner and or operator shall study and underst...

Страница 3: ...stick Please keep the shipping screw if needed for shipping or transport The pump is filled with high quality hydraulic oil at the factory Prior to operation check that the hydraulic fluid level is at the correct fluid level If you need to add fluid unscrew the dipstick and use a small funnel to fill Use only high quality hydraulic fluid Use of any other fluid will void warranty and damage the pum...

Страница 4: ... air nipple not included to the air input port FIG 4 Tighten the air nipple but do not overtighten Connect air source to the hose conector Ensure that air source can dedicate 9 cfm air supply Use a good quality 3 8 air line hose Always secure threaded port connections with high grade pipe thread sealant When using the pump always use on a flat level surface If the pump needs to be fixed to a level...

Страница 5: ... and not to reach the clasped position Fig 5 Fig 6 Priming the Pump If the pump doesn t work properly at first it may have air in the hydraulic system if this happens you will need to bleed the system 1 Place pump on flat surface and depress the treadle RELEASE to clasp position in order to ensure the oil back to reservoir 2 Check the oil level Fill the pump with high quality hydraulic oil if nece...

Страница 6: ...evel Check oil level and top up Pump fails to reach maximum pressure Insufficient air pressure Check air supply must have 100 120 PSI Relief valve incorrectly set Contact the supplier Oil leak in the main hydraulic circuit Check the circuit for leaks and repair as necessary Pump delivers pressurized oil but load is not lifted Oil circulation fault Check if pipelines are obstructed or if cylinder i...

Страница 7: ... 34 Piston Cap 1 35 Lock Washer 3 36 Screw 3 37 Small Piston Circle 1 38 Air Cylinder 1 39 Air Cylinder Cap 1 40 Lock Washer 4 41 Screw 4 42 O Ring 2 43 Spring 1 44 Base For Steel Ball 1 NO DESCRIPTION QTY 45 Steel Ball 1 46 Valve Core 1 47 O Ring 3 48 Washer 3 49 Base For Release Valve 1 50 Valve Pin 1 51 Steel Ball 1 52 Spring 1 53 Valve 1 54 Seal Washer 1 55 Cover 1 56 Ruler 1 57 Rubber Pad 6 5...