RESET
R
I
P
P
L
E
S
T
R
I
K
E
M
O
D
U
L
E
V
I
N
T
E
M
P
G
O
F
U
S
E
V
I
N
2
0
V
D
C
GREEN
RED
WHEN ALL FOUR of the green indicator lights are glowing, the power supply is
operating trouble-free. One or more red lights, when glowing, indicates that a problem exists, and
disables operation of the power supply. The red light(s) latches and remains glowing until the
RESET
button is depressed after the problem has been corrected.
GREEN LIGHTS:
20 VDC:
Indicates that the control board is receiving the correct DC input.
VIN:
Indicates that the AC input voltage is within the correct range (200-240 V.AC).
FUSE:
Indicates that the fuses on the primary boards are good.
GO:
Indicates that the lamphouse interlock circuit is complete, and that DC power is being
applied to the xenon bulb.
RED LIGHTS:
TEMP:
Indicates that the unit is overheated.
VIN:
Indicates that AC input voltage is above or below the correct range (200-240 V.AC).
MODULE:
Indicates that one or more fuses on the primary boards have opened.
STRIKE:
Indicates that the xenon bulb is requiring an excessive number of ignition pulses.
RIPPLE:
Indicates excessive ripple in the output current.
INDICATOR LIGHTS
5
Содержание xenon
Страница 2: ......
Страница 10: ...FIGURE 1 5 See Figure 3 1 2 3 4 6 7 8 9 10 11 12 13 8 ...
Страница 12: ...FIGURE 2 1 2 3 4 5 6 7 8 9 10 11 12 13 5 14 15 16 17 18 17 19 10 ...
Страница 17: ......
Страница 18: ......