INSTALLATION - OPERATION
When positioning the power supply, allow several inches clearance around the power
supply cabinet for unobstructed air flow. If the intake or outlet grilles are blocked, thermal switches
will shut the unit off to prevent heat damage.
Connect the lamphouse DC and control leads to the output side of the power supply
prior to connecting to AC power. Lamphouse to power supply connections, when not terminated in
a MS plug, are illustrated on the INTERCONNECTION DIAGRAM in the lamphouse instruction
manual. Make certain the lamphouse ground lead is connected.
Power leads run to the unit must be of the correct size and type to conform to local
codes. Shield in conduit as required. The power supply will not energize until the circuit breakers
on the side of the cabinet are placed in the ON position.
A four-prong, female plug is furnished to mate to the AC receptacle
mounted to the power supply. Connect 208/230 V.AC three phase input to
terminals X, Y, and Z. Connect single phase input to terminals X and Z
only.
Single or three phase neutral is not required for installation of this unit. Attach
an adequate earth ground to the green ground terminal.
In areas using 380/440 V.AC three phase power (Europe, etc.),
connect the unit for single phase operation only, using (1) phase line on X and
a neutral on Z. AC input as measured across connector terminals X and Z
must not exceed 240 V.AC. Attach an adequate earth ground to the green
ground terminal.
See the warranty information packed with the xenon bulb for correct operating cur-
rent. Do not, at any time, exceed the maximum current level specified by the bulb manufacturer.
Current output to the bulb is set through use of the adjustment potentiometer(s). If
installed in a Strong Xenon Projection Console, the adjustment potentiometer (62-70032) is gener-
ally remoted to the console control panel. When the remote option is not utilized, a potentiometer
printed circuit board assembly (62-70028) is connected directly to the current control receptacle.
Ground prong
keyed
2
CAUTION: This equipment operates at hazardous voltages, and
should be operated by qualified, trained personnel
only. Do not
remove power supply cover panels when the unit is energized.