4
Connections should be made using copper conductors only. The connecting wire and circuit
breakers or fuses must be sized to accommodate the total ampere load as specified on the
equipment module data label.
Strong Pools and Spas only makes electrical recommendations, always consult a certified electrician.
It is recommended that a licensed electrician install the power to your spa, in accordance with
the National Electric Code or any local electrical codes in effect at the time of installation.
The circuit breaker must be dedicated and cannot be shared with any other appliances. It
should be labeled and easily accessible to users.
DO NOT USE EXTENSION OR PLUG-
TYPE CORDS OF ANY KIND.
The use of a shut-off box near the spa is recommended.
Metal surfaces within 5 feet of the spa must be grounded to the spa.
A 120 Volt - 20 Amp GFI rated plug is furnished with the Rio Spa.
Electrical - General Instructions
CAUTION: This spa will not work if more than one GFCI is used on the circuit.
110/220 Volt Rio
Electrical Connections:
Two Wire
& Ground
TERMINAL
BLOCK
Ground (copper or green)GRD
Live (black) Hot Black
Neutral (white) Neutral
Hot Red