background image

10

CONCENTRATED CHLORINATING GRANULES - The minimum chlorine level in the spa should be
at least 2PPM (parts per million).  Chlorine level should be tested frequently and the chemical added
to maintain a safe level of 2PPM.  This type of chemical can be added in quantities of 0.5 ounce per
500 gallons of spa water.  Check the chlorine level at least seven hours or more after adding to
determine the full effect of the added chemical.  Liquid chlorine is not recommended.

ORGANIC POLYMERS - are used in various forms.  These chemicals clear up cloudy or dirty water
appearance and prevent calcium deposits on the inside spa finish, plumbing and heating equipment.
Use as recommended by the manufacturer.

METAL GON - or its equivalent is a chemical that will prevent iron in the spa water from staining the
spa finish.  This chemical is added to the spa water when the spa is filled for the first time or when
refilled.  Use as recommended by the manufacturer.

SILICONE EMULSION - quickly and effectively disperses foam and is completely compatible with
the other chemicals listed.  Use as recommended by the manufacturer.

SPA WATER - should be changed periodically, depending upon frequency of use and other condi-
tions that may affect water suitability. Typically 60 to 90 days is a satisfactory interval under normal
conditions.  With heavy usage, the interval between water changing should be less.

SPA FILTER CARTRIDGE - should be cleaned every 2 to 4 weeks depending on the frequency of
use.  Rinse the filter cartridge with a pressure hose and re-install filter cartridge in the filter housing.
When changing spa water it is good practice to soak the filter cartridge in filter cleaner.  The filter
cleaner is specially made to remove accumulation of oils and other contaminates which will ensure
good, sanitary water and extended filter cartridge life.

ADDING CHEMICALS - to your spa water:  Add to the center of the spa with the pump and the air
blower (bubbles) operating simultaneously.  Make sure the water is heated.  Never add chemicals to
cold water, as this will effect chemical action. Also, never add chemicals directly into the skimmer.

Store all chemicals in a cool, dry place and in such a way as to prevent children and pets from con-
tacting.

WINTERIZING

Before draining, power must be turned off at the GFCI circuit breaker. Attach a garden hose to the
faucet and open it. Water will start to drain. You can use the water to water the garden. You can also
siphon the water from the spa. The drain faucet will not remove all the water. You may have to
remove a small amount of water by hand, using a towel. You must also use a wet-vac to remove the
water from the lines by suction and/or blowing. Water left in the line and jets might freeze and damge
them. To adequately clean out the lines, place the wet-vac over each jet face for 10-15 seconds.
Remove the filter cartridge and do the same to the filter cavity. also, let the water drain from the
heater tube by loosening the black split nuts on each side of the heater tube. Remember to retighten
the split-nuts when completed. Use the wet-vac to vacuum up any water that may have drained on
the spa floor area.

Note: Damage caused by improper winterizing will not be covered under warranty. You may
want to contact a professional for proper winterizing.

Spa Maintenance

Содержание RIO

Страница 1: ...MANUAL P O Box 108 Northumberland PA 17857 1 800 STRONG 9 1 800 787 6649 1 9 07 CAUTION More than one GFCI used on the electrical circuit will render this spa inoperable This spa must be on a dedicated circuit ...

Страница 2: ...pa Maintenance 9 10 Jets Valves Injectors Suction 11 Warranties 12 Safety Precautions 13 Registration Card 13 Be sure to locate the Registration Form at the back of this owner s manual Please fill it out and send it to Strong Pools and Spas immediately Failure to return the registration card and a photocopy of the sales receipt within 30 days of purchase voids all warranties provided by Strong Poo...

Страница 3: ...ating a Lifestyle that Lasts a Lifetime With proper care operation and maintenance your spa will provide your family many years of comfort and pleasure Please take time to read all the instructions before you install your Strong Pools Spa Rio spa This manual explains safety precautions installation instructions operating directions and maintenance procedures If you have any questions after reading...

Страница 4: ... 10 15 minutes and for young children Long exposure at higher temperature can result in dizziness and or hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98 F 36 7 C The symptoms of hyper thermia include dizziness fainting drowsiness or lethargy The affects of hyperthermia include Unawareness of impendin...

Страница 5: ...oom location landscaping and evening lighting The spa with water is very heavy if the spa is placed on flooring or decking be sure the structure is strong enough to support the weight The necessary support should be at least 75 pounds per square foot Install your spa in a way that will allow easy access to the equipment door Storage area for maintenance equipment and chemicals storing chemicals in...

Страница 6: ...ffect at the time of installation The circuit breaker must be dedicated and cannot be shared with any other appliances It should be labeled and easily accessible to users DO NOT USE EXTENSION OR PLUG TYPE CORDS OF ANY KIND The use of a shut off box near the spa is recommended Metal surfaces within 5 feet of the spa must be grounded to the spa A 120 Volt 20 Amp GFI rated plug is furnished with the ...

Страница 7: ...inutes every 30 minutes to detect the spa temperature and then to heat to the set temperature if needed depending upon mode When the low speed turns on automatically it cannot be deactivated from the panel however the high speed may be started Light There are several color options in our spas and by pressing the light button in quick succession the customer can cycle through the different lighting...

Страница 8: ...liances on this circuit and it will need a 20 amp breaker Strong Industries recommends that only one GFCI be present on the circuit and that the owner follows any local building codes Power up spa Controls will read the program r59 then 30 seconds top control should read PUR This is setting was created in order to clear the pump of any air unwanted air in that area A Most spas do not require pump ...

Страница 9: ... change program call tech support FILTRATION Proper filtration is an important key to maintaining the clarity of your spa s water The filter system is designed for unsurpassed effectiveness at removing debris and suspensions from the water anytime the water is circulating Your control panel is set to filter for two hours every twelve hours A two speed pump is supplied with your spa that provides f...

Страница 10: ...e turned off Heat not working Blinking decimal but no heat 1 Give spa time to heat up and be sure to cover 2 Bad heater call tech support Water temperature not close to displayed temperature 1 Check thermister is located in thermalwell and insulated by rubber gasket 2 Make sure that air vents are unobstructed LOC 1 Press Heat and Jets key simultaneously This will activate and deactivate this code ...

Страница 11: ...pment Since the water capacity of your spa is far less than that of a swimming pool the chemical reaction caused by the presence of one or more persons in the spa is more rapid and pro nounced In other words it is much more difficult to maintain the proper pH balance in a spa than in a swimming pool For these reasons it is important to check frequently the total alka linity of the water the pH lev...

Страница 12: ...ridge in the filter housing When changing spa water it is good practice to soak the filter cartridge in filter cleaner The filter cleaner is specially made to remove accumulation of oils and other contaminates which will ensure good sanitary water and extended filter cartridge life ADDING CHEMICALS to your spa water Add to the center of the spa with the pump and the air blower bubbles operating si...

Страница 13: ...et 2 Jets Valves Injection and Suction Top Air Control Valve Air Control Valve should be turned off when spa is not in use The spa will heat up faster Bottom Suction Turn counter cloc k w i s e t o o p e n ...

Страница 14: ...ation in which it was not designed spa shell damage caused by excessive heat build up due to failure to cover the spa while empty of water and or exposure to direct sunlight any damages caused by improper maintenance of spa water chemistry or by any undissolved spa chemicals which may cause bleaching of the spa shell and erosion or discoloration of stainless jets any repairs that are done by any o...

Страница 15: ...in cover Do not modify the suction or filtration systems 4 Exercise caution when entering or leaving the Hot Tub When changing positions be sure of your footing before applying your full weight as water refraction can be misleading 5 Do not stay in the water for extended periods of time Set reasonable time limits Leave the Hot Tub cool down take a shower relax then return for another stay Points o...

Страница 16: ...AY THROUGH FRIDAY 8 30 AM 5 00 PM E S T 570 275 2700 GIVE YOUR NAME TELEPHONE NUMBER AREA CODE NAME OF SPA NAME OF MODEL QUANTITY AND TYPE OF PARTS REASON FOR REQUEST A DAMAGED B DEFECTIVE PLACE STAMP HERE STRONG POOLS SPAS 3204 Point Township Drive Rte 11 P O Box 108 Northumberland PA 17857 USA ...

Отзывы: