THE LAMPHOUSE is supplied with a 13 foot cable assembly containing the two DC leads,
the ground wire, and all AC control leads. The cable assembly is terminated with (2) multiple pin, keyed MS
connectors which mate to receptacles on the lamphouse and xenon power supply cabinet. The AC hook-up to
the xenon power supply is detailed in the power supply manual; AC connectors must comply with all local
electrical codes.
THE OPTICAL SYSTEM incorporates a newly-designed lens mechanism. Spotlight opera-
tors familiar with earlier type Strong spotlights are urged to study the section following in this manual entitled
OPERATION OF THE OPTICAL SYSTEM and to practice the operation of the Super Trouper II prior their
first performance. The spot size control (trombone) handle is drawn
back
to spot and pushed
forward
to
flood, which is the reverse of earlier type Strong optical systems. The spot edge is focused by rotating the
focus knobs located behind the boomerang on the left and right sides of the optical system.
FADE-OUT, CHOPPER, AND IRIS CONTROLS are positioned in the same configuration as
earlier Strong spotlights. All optical system controls are accessible for right- or left-hand operation. The color
boomerang is easily reversed to position the color arms on either side. Operation of the self-canceling boomer-
ang remains unchanged, and standard Strong nine-inch gel frames are used.
WHEN TRANSPORTING the spotlight, it is recommended that the xenon bulb be removed
and placed in its original shipping carton with the cover on the bulb to insure against breakage. The bulb, after
cooling to room temperature, may remain mounted in the lamphouse if moving the spotlight from one position
to another within the arena or auditorium. Reasonable care should be exercised; breakage caused in handling is
not
covered by the xenon bulb warranty.
IF AT ANY TIME you have a suggestion, or desire aid in securing anticipated results, please
feel free to write directly to STRONG INTERNATIONAL, 4350 McKinley Street, Omaha, Nebraska 68112.
ST2/002
Содержание SUPER TROUPER II
Страница 2: ......
Страница 5: ...ST2 003 ...
Страница 26: ...Super Trouper II Lamphouse Xenon Bulb Ignition Monitor Circuit ST2 024 ...
Страница 27: ...Super Trouper II Control Circuit ST2 025 ...
Страница 30: ...23976S DIGITAL DISPLAY CONTROL CIRCUIT Page 1 0f 3 ST2 028 ...
Страница 31: ...23976S DIGITA L DISPL AY CONT ROL CIRCU IT Page 2 0f 3 ST2 029 ...
Страница 32: ...23976S DIGITAL DISPLAY CONTROL CIRCUIT Page 3 0f 3 ST2 030 ...
Страница 33: ...1 2 3 4 5 6 7 8 9 10 11 FIGURE 1 SUPER TROUPER II Parts List ST2 031 ...
Страница 43: ...FIGURE 5 ST2 041 ...
Страница 49: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 FIGURE 7 24124 COLOR BOOMERANG ASSEMBLY ST2 047 20 ...
Страница 51: ......
Страница 52: ......