4.4 Cycle time programming
Automatic valve will select right regeneration cycle times automatically based on filters system
size. Do not chance any settings.
4.4.1 Regeneration modes
Below is described the regeneration cycles of automatic valve that is used in AG-CAB filters.
C0 = Normal filtering stage (not shown)
C1 = Regeneration back wash
C2 = Suction of the brine
C3 = Slow flushing
C4 = Pressurizing / prepared
C5 = Quick flushing
C6 = Backwash 2 (only in valve 255)
C7= Quick flush 2 (only in valve 255)
C8= Fill of brine tank with water
Picture 8. regeneration cycles
4.4.2 Manual regeneration
Manual regeneration can be done with two ways:
Option 1. Press the REGENERATE button shortly. Regeneration symbol starts blinking on the
screen. Valve executes additional regeneration cycle on the pre-set time (2:00 as standard).
Option 2. Press the REGENERATE button for five seconds and the regeneration cycle starts
immediately.