5.3.2
Magnetic insulation
SKB-0171
4
3
DD 592014 / Fig. 6
3
Armature plate
4
Carrier
103
Spacer bush
In order to prevent a reduction in the transmissible torque and an increased switching time due to magnetic
stray flux, the following constructional measures for magnetic insulation must be taken:
• The shaft or spacer bush (103) under the armature plate (3) must be at least 4 mm smaller than the bore (D)
of the armature plate in external diameter (D4). If that is not possible, the shaft and the spacer bush must be
made of non-magnetisable material.
• The carrier (4) is finished as standard in a non-magnetisable material, e.g. brass, with a minimum hardness
of 140 HB 10. However, under specific conditions the use of steel is also possible. Should the carrier be
made of steel, the application case must be checked. In this case, it is necessary to consult with Stromag’s
Customer Care department.
23
Mounting instructions Electromagnetic tooth clutch EZB • No. 590-00000 E • 10/2017
Содержание EZB
Страница 2: ......
Страница 5: ...11 2 Serviceadresse 38 V Montageanleitung Elektromagnet Zahnkupplung EZB Nr 590 00000 E 10 2017...
Страница 6: ...VI Montageanleitung Elektromagnet Zahnkupplung EZB Nr 590 00000 E 10 2017...
Страница 26: ...Ersatzteilbestellung siehe Kapitel 11 20 Montageanleitung Elektromagnet Zahnkupplung EZB Nr 590 00000 E 10 2017...
Страница 45: ...39 Montageanleitung Elektromagnet Zahnkupplung EZB Nr 590 00000 E 10 2017...
Страница 48: ......
Страница 51: ...11 2 Service address 38 V Mounting instructions Electromagnetic tooth clutch EZB No 590 00000 E 10 2017...
Страница 52: ...VI Mounting instructions Electromagnetic tooth clutch EZB No 590 00000 E 10 2017...
Страница 91: ...39 Mounting instructions Electromagnetic tooth clutch EZB No 590 00000 E 10 2017...