O P E R AT I O N

Once the system has been plumbed and wired in accordance with this manual it is time to switch the mains 
supply on.

When power is supplied to the unit the indicator light will illuminate to show that the system is ready, and 
begining to heat the water.

The dial on the outside of the case can be used to control the temperature that the internal water store 
is heated to, turning this higher will increase the store temperature, turning it lower will decrease it. We 
recommend adjusting the thermostat over a few days until the desired temperature is achieved. Remember 
to only run the heater at the temperature required to avoid wasting energy.

In the event of overheating there is a safety cut out stat built into the unit. This has a resettable switch that 
can be pressed to reset and can be found on the immersion heater inside the unit. We recommend that you 
have a proper engineer service the unit and this is not attempted by the user. 

The immersion heater is located below the grey plate on the underneath of the unit. If the unit has been 
installed so this plate is inaccessible please disconnect the unit from the mains, isolate the water supply, 
drain down, and remove the unit from the wall for maintenance.

Before attempting to maintain the unit please ensure you have isolated the electrical supply.

M A I N T E N A N C E

Before attempting to maintain the unit please ensure you have isolated the electrical supply, and should 

only be performed by a qualified professional.

This unit is a mains pressure hot water unit, and it is recommended that this device be serviced annually 
to ensure a long and healthy lifespan.

Your water heater includes a Magnesium sacrificial annode as part of the immersion heater assembly. The 
annode is present to ensure that your water heater does not corrode, should this device not be serviced, 
the tank may corrode. The location of the immersion is as described above and is accesible from the grey 
service hatch on the bottom of the unit.

The annode should be inspected annually and the condition checked, if the annode is sufficiently corroded 
it should be replaced to ensure the protection of your water heater.

Additionally the pressure relief valve should be inspected annually, as well as the expansion vessel, check 
valve, and pressure reducing set if fitted.

G U A R A N T E E

Your 

Strom-Electrical

 water heater is guaranteed for a period of 12 months from the date of purchase. 

The unit is only guaranteed if the water heater has been installed and maintained in accordance with these 
instructions. Full guarantee information can be found at: 

www.strom-electrical.com/guarantee

6.

Содержание SEUS6L

Страница 1: ...STROM ELECTRICAL www strom electrical com U n d e r s i n k O v e r s i n k H e a t e r I n s t a l l a t i o n M a n u a l I s s u e 1 2 0 1 6 2 0 1 7 STROM ELECTRICAL www strom electrical com ...

Страница 2: ...be installed and maintained regularly by a qualified professional in accordance with current electrical and plumbing regulations The included Safety Pressure Relief Valve MUST be fitted in accordance with this manual Your Strom Electrical water heater MUST be installed in the correct orientation in accordance with page 5 The unit can be sited above or below the taps so long as it is in the correct...

Страница 3: ...n from the heater to the system pipework should be made using flexible stainless steel hoses this facilitates the operation of the unit and also makes future maintenance easier The pipework used should be capable of withstanding 7 5 bar of working pressure and temperatures in excess of 80o C The included safety relief valve must always be fitted without exception and should have no obstructions wh...

Страница 4: ...Vessel Check Valve Pressure Reducing Valve Heater Expansion Vessel Check Valve Closest Cold Draw Off Pressure Reducing Set Service Valve Not Supplied Discharge To Drain Heater Expansion Vessel Check Valve Closest Cold Draw Off Service Valve Not Supplied Discharge To Drain Heater Closest Cold Draw Off Service Valve Not Supplied Pressure Relief Valve Discharge To Drain Minimum Distance Required To P...

Страница 5: ...sure your water heater is correctly earthed As previously recommended please ensure that you unit has been filled correctly flushed and all debris and airlocks have been removed before turning your water heater on By bypassing this step you risk irreversible damage to your water heater that will not be covered by your warrenty Electrical connections can be made via an external time clock if requir...

Страница 6: ...l for maintenance Before attempting to maintain the unit please ensure you have isolated the electrical supply MAINTENANCE Before attempting to maintain the unit please ensure you have isolated the electrical supply and should only be performed by a qualified professional This unit is a mains pressure hot water unit and it is recommended that this device be serviced annually to ensure a long and h...

Страница 7: ...ailed Please replace the thermostat Insufficient Amounts Of Hot Water Available The heater has been undersized Please replace the heater with one of an adequate size The unit has been mounted the wrong way round Please mount the heater ensuring the pipes are facing downwards The Thermostat has failed Please replace the thermostat The Unit Has Begun To Leak Faulty plumbing connection Please check a...

Страница 8: ...STROM ELECTRICAL www strom electrical com w w w s t r o m e l e c t r i c a l c o m ...

Отзывы: