Safety Precautions 

These Safety Precautions are to ensure that you use the product safely and correctly and to prevent 

harm or injury to users and other people. To prevent injury or harm please read and understand the 

below text. 

 WARNING

Indicates handling prior to reading may 

cause serious injury or death.

 CAUTION

Indicates handing prior to reading may 

cause physical harm or damage. 

Disclaimer

We are not responsible for any damage to equipment or facilities during the installation, use,

or removal of the product.  

We are not responsible for damages caused by earthquakes, thunder, wind, fire, flood, or a

third party to the machine. Negligence, misuse, or abnormal conditions resulting in damage 

are also not our responsibility. 

We are not responsible for damages caused by malfunctions due to combinations of

equipment or software not involving Strex.  

We are not responsible for any incidental damage caused by the use or misuse of this

product including loss of business income, interruption of business, loss of stored data, theft 

of machine, etc. 

WARNING 

 

Please do not place water or water-containing vessels on or near the machine:  

• 

Cups, vials, tubes etc. containing water should not be located on or near the device.

• 

Be careful as to not wet the connection cable or power cable. Failure to do so could

lead to fire, electric shock etc. Do not disassemble or reconfigure. 

• 

Do not attempt to disassemble or reconfigure this machine. Doing so may result in

fire, electric shock, or equipment malfunction. Please do not use under abnormal 

conditions. 

• 

If the machine is overheating, emitting a strange odor, etc. disconnect the power cable

from the outlet immediately. Failure to do so may result in a fire or electric shock. 

Do not use voltage other than the indicated power supply voltage. Failure to do so may

result in fire or electric shock. Be sure to use the supplied power cable.

1

6

 

Section 6: Safety Instructions 

and Precautions

Please read this section carefully before using the instrument. Items in this section alert the user to 
operational dangers that, if not followed, may damage the instrument or, more significantly, result in
serious injury or death of the user. To ensure safe operation of the instrument, it is therefore
imperative that you follow these instructions carefully.

Power cable 

To avoid possible short circuit, shock, or fire

••

Only use the power cable provided with the Cell Strain Instrument.

••

Do not touch the cable with wet hands.

••

Do  not use the  machine  with  other voltage  than  that specified. In  some cases, a
transformer may be used for compatibility. Inappropriate current may result in the machine
overheating, short-circuiting, and/or fire may occur.

••

Do not staple around the power cable.

••

Do not bend the cable or place heavy objects on it.

••

When pulling a connector from an outlet, pull to disconnect gently by holding its plug, not
the cable.

••

Do not plug many objects into a single electrical outlet since it may cause fire.

••

If you are using an extension cord, ensure it can withstand the total current to be used.

••

Disconnect power from the unit when it is not in use.

••

Connect the instrument to a power-surge protected outlet.

Installation Location and Environment

••

Keep the instrument on a stable, leveled floor or a table, secure from vibrations. Be sure
you have enough space.

••

Do not store the instrument in a humid or dusty place. Over time, excessive humidity or
dust may cause deterioration that can result in an electrical short-circuit and possibly fire.

••

Do not use the machine in a place where the temperature is excessively high. Do not
place and run the machine near a heater or in a place being exposed to a direct sunlight.

••

To avoid possibly explosion, never place and run the instrument nearby the presence of
flammable solid substance, liquid, or gas. It may cause explosion or fire.

••

Use the machine in well lit conditions.

••

Do not use the machine outdoors in direct sunlight or rain, which may cause overheating
or short circuit.

Содержание STB-1400-04

Страница 1: ...STREX Cell Strain Instrument Catalog STB 1400 04 User Manual ...

Страница 2: ...in Chamber 5 Section 2 Use of the Cell Strain Instrument 6 Preparation of Cell Strain Instrument 6 6 7 System Operation Culturing Cells in the Silicone Chambers Preparation of Silicone Chambers 8 Section 3 Strain Parameters 10 Section 4 FAQ 11 Section 5 References 13 Section 6 Safety Instructions 15 Section 7 Warranty 18 ...

Страница 3: ...r length adjusting knob Use the knob to adjust the distance of chamber brackets to maintain tension on the chamber The bottom of the chamber should be taut Connectors Use Connector Cable to connect Control Unit to Stretch Unit Alignment Pins Holds Strain Chamber Brackets in place Strain Chamber Brackets Each chamber is mounted on four pins two pins on each bracket Mounting Stage Brackets sit on to...

Страница 4: ...wer source Strain Ratio Use upper and lower buttons to increase and decrease stretch ratio Strain Frequency Selector Use upper and lower buttons to adjust cycle frequency Water Pump Switch Use to turn on and off the pump that circulates water to cool the motor System coolant inlet outlet valves Be sure to supply cool water when in operation Failure to do so may lead to overheating inside the incub...

Страница 5: ...5 Silicone Strain Chamber ST CH 04 0 10m m Chamber Dimensions 20mm x 20mm x 10mm 31m m 18m m 25m m 40m 4 places for pins Chambermembrane thickness 0 1mm ...

Страница 6: ... Coolant Inlet and Outlet Valves see Section 1 To release the metal plugs from the Stretch Unit push backward on the outer metal rings around the valves The single larger black plug supplies electricity to the Stretch Unit this plug has to be in the correct orientation to fit properly The other end of the Connector Cable has 2 exposed latex tubes which fit onto the System Coolant Inlet and Outlet ...

Страница 7: ...ch cycle may damage the motors 4 Push the Start Button to start the stretch unit 5 After 5 minutes stop the stretching and check the condition of the cells If the cells have not detached proceed with your experiment If the cells are detached the adhesion matrix coating was probably insufficient Recoat the chambers Culturing Cells in the Silicone Chambers 1 Seed cells at the appropriate concentrati...

Страница 8: ...rging in 70 ethanol rinsing with water then drying in a sterile environment Place the sterile silicone chambers in a Petri dish in preparation for coating Fibronectin Coating Preparation of fibronectin solution 1 Dilute human or bovine fibronectin to a final concentration of 50 to 100 ug ml in Phosphate Buffered Saline PBS Coating with fibronectin solution 1 Pour 3 ml of the fibronectin solution i...

Страница 9: ...be Coating with collagen solution 1 Coat chamber with a thin layer 2 Aspirate excess 3 Dry in biological safety cabinet at 25 C or below The chamber can be stored at the same temperature 4 Wash the chamber twice with culture medium 5 If coating is successful water will not be repelled The PDMS silicone chambers are very hydrophobic with two methyl bases on the surface Cells adhere to the fibronect...

Страница 10: ...s min 0 5 Hz Sine wave Stretch 1 sec contract 1 sec repeat 2 15 cycles min 0 25 Hz Stretch 2 sec contract 2 sec repeat 3 10 cycles min Sine wave Stretch 3 sec contract 3 sec repeat 4 20 cycles min Square wave Hold 0 5 sec stretch 1 sec hold 0 5 sec contract 1 sec repeat 5 10 cycles min Square wave Hold 2 sec stretch 1 sec hold 2 sec contract 1 sec repeat 6 1 cycle min Square wave Hold 29 sec stret...

Страница 11: ...ding your cell suspension in the chamber Q3 Cell attachment on the stretch chamber was confirmed by microscopy But the cells detached from the chamber surface after stretching the cells A3 Try seeding your chambers at a lower concentration of cells Over confluent cells generally adhere to neighboring cells rather than to the base matrix dish surface When an excess amount of cells are put in a cult...

Страница 12: ...on Wash the cells once with PBS Add cell extract buffer directly into the chamber and collect the cell extract by using a cell scraper 3 RNA Wash the cells once with PBS for RNApreparation Add RNAextraction buffer directly into the chamber and collect the cell extract by using a cell scraper Q6 I want to use recombinant cells for an experiment A6 Direct transfection of cells in the strain chamber ...

Страница 13: ... 615 619 1998 8 Pp125FAK is required for stretch dependentmorphological response of endothelial cells K Naruse T Yamada X Sai M Hamaguchi and M Sokabe Oncogene 17 455 463 1998 9 OrientationChangeof Cardiocytes Induced byCyclic Stretch Stimulation TimeDependencyand Involvementof ProteinKinases K Kada K Yasui K Naruse and J Toyama J Mol Cell Cardio 31 247 259 1999 10 Molecular Identification of a Eu...

Страница 14: ...annel bymembranestress crated with amphipaths Mol Membr Biol 22 6 519 527 2005 21 Stretch induced cell proliferation ismediated byFAK MAPK pathway Life Sci 76 24 2817 2825 2005 22 Fabrication of reconfigurationprotein matrices bycracking X Zhu K Mills P Peters J Bahng El Liu J Shim K Naruse M Csete M Thouless S Takayama Nature Materials 4 403 406 2005 23 Involvementof reactive oxygen speciesin cyc...

Страница 15: ...nnect gently by holding its plug not the cable Do not plug many objects into a single electrical outlet since it may cause fire If you are using an extension cord ensure it can withstand the total current to be used Disconnect power from the unit when it is not in use Connect the instrument to a power surge protected outlet Installation Location and Environment Keep the instrument on a stable leve...

Страница 16: ... 16 Section 6 Safety Instructions and Precautions Please read this section carefully before using the instrument Items in this section alert the user to operational dangers that if not followed may damage the instrument or more significantly result in serious injury or death of the user To ensure safe operation of the instrument it is therefore imperative that you follow these instructions careful...

Страница 17: ...tlet for safety 17 Section 6 Safety Instructions and Precautions Please read this section carefully before using the instrument Items in this section alert the user to operational dangers that if not followed may damage the instrument or more significantly result in serious injury or death of the user To ensure safe operation of the instrument it is therefore imperative that you follow these instr...

Страница 18: ...amage resulting from an attempted repair or modification of the instrument by the user Damage caused by unavoidable external causes such as earthquakes lightening fire flood gas leak power surges or other acts of providence 3 Strex is free from any responsibility for effects or loss or damages arising from the result of the machine operation This warranty assures that Strex will repair our product f...

Отзывы: