6.17 System Menu
This menu allows settings reserved for qualified personnel. Because of this, the menu is keyword protected.
Ex factory, the keyword is
2111
.
To enter the keyword, confirm the selection ‚System Menu‘ with P3 (SET). Now it is possible to use P4 (^) and P6 (v) to increase or decrease
the displayed digit. Confirm the desired digit with P3 (SET). After that, the cursor moves to the next position until all 4 digits are filled in.
After the fourt digit is confirmed with P3 (SET) and the keyword is correct, the system menu will open.
Important: Changes in the system menu can cause malfuntions or damages to the boiler and the system!
6.18 operation Parameters
Pellet Auger
Parameter
Recommended
Description
C01
0.5
Ignition
C02
0.8 – 1.0
Stabilisation
C03
0.8
Power level 1
C04
1.6
Power level 2
C05
1.8 – 2.0
Power level 3
Boiler Fan (RPM)
Parameter
Recommended
Description
U01
1250 – 1400
Ignition
U02
1600
Stabilisation
U03
1550
Power level 1
U04
1600
Power level 2
U05
1650 – 1700
Power level 3
P23
1700
Burn out
Time Programme
Parameter
Recommended
Description
Additional
T02
40
Igniter preheat time
T03
40 – 50
Auger r un time prior to ignition (for pellet
starting load)
There have to be enough pellets in front of the
igniter hole!
T04
450
Timespan between start and normal ope-
ration
T06
250
Stabilisation time
Durin this time span, the boiler temperature
has to rise 7°C.
Controller
Pag 19/45
DMAN802000055- SY250 Hydro Technical Manual
8.4
System Menu
This menu allows to enter into Technical Menu. The access
is protected by password.
Push
P3
to enter in editing mode,
P4
and
P6
to
increase or decrease
the selected digit. Push
P3
to save the
digit and pass to the next. Push
P1
to cancel the digit or exit from Menu.
The default Password is 0000
.
Display
Description
Auger Menu
Combustion Fan Menu
Combustion Fan 2 Menu
Heating Fan Menu
Thermostats Menu
Extinguishing Thermostats Menu
Timer Menu
Default Settings Menu
Enables Menu
Air Flow Regulator Menu
Temperature Delta Menu
Pressure Sensor Menu
Counters Menu
Outputs’ Test Menu
Restore Default Values Menu
8.4.1
Auger Menu
Menu that allows to set the Auger work time. The values are referred to the current combustion recipe
(selected in the User’s Menu); each value is a functioning power. If a
value is set to 0 seconds the Auger is
disabled for the corresponding power. The Auger regulation can be set with a step of 0.1 seconds.
Code
Description
Min
Max
Unit
C01
Ignition Power
0
60
[s]
C02
Stabilisation Power
0
60
[s]
C03
Power 1
P27
60
[s]
C04
Power 2
P27
60
[s]
C05
Power 3
P27
60
[s]
C06
Power 4
P27
60
[s]
C07
Power 5
P27
60
[s]
C08
Power 6
P27
60
[s]
C09
Periodic Cleaning Power
0
60
[s]
C10
Second Ignition Power
0
60
[s]
C11
Modulation Power
P27
60
[s]
P05
Auger Period
4
60
[s]
P15
Calibration step of Auger work time
1
20
[%]
P27
Minimum work time
0
60
[s]
Keyboard Menu
System Menu
_____
PASSWORD?
________
- - - -
Auger
__________
Exhaust Fan
Exhaust Fan 2
Heating Fan
Thermostats
Tempi
Extinguishing Th
Timers
Default Settings
Enables
Air Flow Regulator
Sensore Pressione
Contatori
Delta
Pressure Sensor
Counters
Outputs’ Test