27
ATI SP 80, 120, 220, 300, 400 – INSTALLATION INSTRUCTIONS
Sept - 01
WARNING :-
The unit should have an internal inspection of the water tank
and cleaned at least once a year or the Warranty will be
invalidated. However depending on the local water conditions
and the usage of the water heater additional inspection may be
required. We would recommend that within the first six months
of a new installation an internal inspection is undertaken to
determine the frequency of future inspections.
WARRANTY
NORMAL STREBEL WARRANTY APPLIES
The warranty is valid provided that the installation standards
and everything contained in the booklet are complied with.
ATI
80
120
220
300
400
CAPACITY
Litre
75
115
220
300
400
NOMINAL INPUT
Btu/h
17,060
17,060
97,242
105,772
105,772
kW
5.0
5.0
28.5
31.0
31.0
NOMINAL OUTPUT
Btu/h
16,036
16,036
88,029
95,536
95,536
kW
4.7
4.7
25.8
28.0
28.0
COMBUSTION EFFICIENCY
94%
94%
92%
92%
92%
10 MINUTE OUTPUT AT 54° C
(Storage Water At 60°C - Cold Water At 10°C)
Lt/10 mins
91
140
305
401
515
CONTINUOUS OUTPUT WITH A 44° C TEMPERATURE DIFFERENCE
Lt/h
91
91
502
568
568
TIME TO RECOVER WITH A 44° C TEMPERATURE DIFFERENCE
min
44
71
26
34
43