ATI SP 80, 120, 220, 300, 400 – INSTALLATION INSTRUCTIONS
Sept - 01
A
The unit needs to be connected to a 230 volt single-phase electrical supply via the 3 core ca-
ble supplied. A double pole switch should be fitted in the vicinity of the equipment to allow for
isolation
of mains supply
and protected with a 3 Amp fuse. This supply can be switched by a
time clock if required.
B
The permanent electronic anode also requires its own UN-interrupted 230 volt single phase
electrical supply and protected with a 3 Amp fuse. The anode is mounted in the inspection
and clean out flange on delivery, the Wall mounted socket, Potentiometer and Loom are in a
box with the fan unit these all need to be assembled as shown above.
WARNING
IF THE PERMANENT ELECTRONIC ANODE IS NOT CONNECTED TO A
PERMANENT 230 VOLT SUPPLY THE WARRANTY WILL BE INVALIDATED
ELECTRONIC ANODE – ATI SP 220, 300 & 400