![Strebel ASCONA A Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/strebel/ascona-a/ascona-a_installation-operating-and-maintenance-manual_1384097004.webp)
12/06/00
Page 4
ASCONA ‘A’ & ‘APV’ INSTALLATION INSTRUCTIONS
A-3
A-4
L
mm
365
450
P
mm
600
600
ØA Flow
inches
1"
1"
ØB Return
inches
1"
1"
ØC Gas supply
inches
½"
½"
G
mm
135
205
H
mm
80
80
ØI Flue size
mm
130
130
M
mm
40
40
ØS
mm
½”
½”
Type and No of Sections
PVA-3 PVA-4
Nominal output
kW
18.2
27.5
Nominal input
kW
20.2
30.5
Supply Pressure – Natural gas
mbar
20
20
Supply Pressure – LPG
mbar
37
37
Burner Pressure – Natural gas
mbar
14.8
14.5
Burner Pressure – LPG
mbar
31.5
30.8
Burner injectors – Natural gas
mm
2.6
2.6
Burner injectors – LPG
mm
1.75
1.75
Gas consumption – Natural
M³/h
2.33
3.44
Gas consumption – LPG
Kg/h
1.71
2.52
Water Resistance 10ºC differential
mbar
9.5
20
Water content
Litres
10
12.5
Flue gas volume
G/s
0.017
0.021
Flue gas temperature
ºC
106
119
Electrical supply for unit
V/Hz
230/50
230/50
Wattage
W
40
40
Shipping weight
Kg
94
118
ASCONA ‘APV’ TECHNICAL DATA – TABLE 2
ASCONA ‘APV’ Heating pump curve