An error has occurred while using AutoCal. This will
happen when the motor is not connected or the enter
button has been pressed to cancel it.
Pressure switch activated or pump disconnected
A dead end has been detected. If this is not the case,
try increasing the calibration value.
This message will start to flash when the battery is low
(<11.0V). If the battery is below 10.5V the pump will be
disabled to protect the battery (unless low battery cut-
off is disabled)
An over current has been detected, the controller has
shut down the pump to protect itself. Lower the flow
rate and check the hose for blockages.