Streamline SFC05-09 Скачать руководство пользователя страница 4

®

6

W: www.streamline.systems   E: [email protected]   T: +44 (0)1626 830 830

W: www.streamline.systems   E: [email protected]   T: +44 (0)1626 830 830

7

4

Operating Warnings 

Operating Warnings 

Set Up Auto Calibrate 

Important

Your battery is at risk of permanent damage if you disable low battery cut-off 

and continue to use your controller for long periods when the battery voltage 

has fallen below +10.5V. 

Adjust the flow settings carefully. Repeated false dead-end detection indicates that the Cal value 
should be increased (less sensitive).

For safety wire through the pump pressure switch. (The pressure switch can be bypassed if  
absolutely necessary - the unit will protect itself under normal conditions.)

This is a WATER PUMP controller: it will not work with air in the system. Always prime the system 
before starting work. If air in the system causes false dead-end detection, increase Cal value until air 
is removed.

Do not set the Cal value too high. Setting it higher than necessary places extra strain on both the 
pump and the controller in a dead end situation. This can result in damage to both the pump and 
your controller.

Specification 

Value

Supply Voltage 

11 - 15 VDC

Maximum Current 

15A

Typical Drive Current 

8A

Voltmeter Accuracy 

+ - 100mV

Enclosure Material 

ABS

Water Resistance 

IP65

Dimensions

115 x 65 x 40 (mm)

Working Temperature 

0 - 40 Deg C

5

Set Up Auto Calibrate

Connect your hose and pole + brush to the pump. 
Turn on the controller by pressing the power button.

Press and hold the up and enter buttons to  
calibrate. CAL will be displayed. 

To select Auto Cal continue to press the down  
button until AUt is displayed. Press the enter  
button to start. Auto Cal starts from C99.  

After several moments the calculated CAL value 
(e.g. C50) will be displayed and the controller is 
ready to use. Press enter to exit calibration. 

Press up until the display shows 30.

Display 

Button

STREAMLINE

Содержание SFC05-09

Страница 1: ...INSTRUCTION MANUAL STREAMLINE SFC05 09 SFC16 Codes INSTR SFC ...

Страница 2: ...manufacturers standard terms and conditions of sale We have an in house technical helpline able to answer most of your questions relating to the capabilities and functionalities of all STREAMLINE products If we get it wrong we will put it right If you are sent a wrong item we will immediately attend to sending you the correct item and arrange a collection of the wrong item without any quibbles STR...

Страница 3: ...eplacement part This warranty excludes the following conditions and circumstances which are at the discretion of STREAMLINE Wear and tear misuse abuse improper maintenance frost damage the use of chemicals other than those supplied or approved by STREAMLINE improper installation or repair unauthorised modification incidental or consequential costs loss or damage service labour or third party charge...

Страница 4: ...m causes false dead end detection increase Cal value until air is removed Do not set the Cal value too high Setting it higher than necessary places extra strain on both the pump and the controller in a dead end situation This can result in damage to both the pump and your controller Specification Value Supply Voltage 11 15 VDC Maximum Current 15A Typical Drive Current 8A Voltmeter Accuracy 100mV E...

Страница 5: ... cut off that stops your pump when the battery voltage is below 10 5V press and hold the down and enter buttons Then use the up or down button to select ON or OFF Press enter to save NOTE ON keeps your battery protected 6 Operation To select Auto Cal continue to press the down button until AUt is displayed Press the enter button to start Auto Cal starts from C99 Display Button Press enter to displa...

Страница 6: ...tch activated or pump disconnected A dead end has been detected If this is not the case try increasing the calibration value This message will start to flash when the battery is low 11 0V If the battery is below 10 5V the pump will be disabled to protect the battery unless low battery cut off is disabled An over current has been detected the controller has shut down the pump to protect itself Lowe...

Страница 7: ...Hamilton House 8 Fairfax Road Heathfield Industrial Estate Newton Abbot Devon TQ12 6UD United Kingdom Telephone 44 0 1626 830 830 Email sales streamline systems Visit www streamline systems ...

Отзывы: