5
Malfunctions and Troubleshooting
Malfunctions and Troubleshooting
Maintenance
During the usage of the
HIGHLINE™
high pressure system, there may be some small
troubleshooting to undertake:
Care and maintenance of your
HIGHLINE™
high pressure system will ensure it is well looked after
and running smoothly every time.
It is recommended to run an inspection quarterly examination before each use, 3 month
and 12 months.
i. Fluctuating pressure at the lance
ii. Pump running normally but pressure is low
vi. Oil dripping from pump/gearbox/engine
vii. Excessive vibration in lance/delivery line
iii. Pump active but very noisy
iv. Presence of oil in the water
v. Water dripping from under the pump
a.
Blocked inlet water filter or poor water supply – check, clean or replace
if needed
b.
Pump sucking in air – ensure all seals are firm, check integrity of suction
hose and connections
a.
Pressure regulator valve needs adjustment
b.
Pump sucking in air – ensure all seals are firm, check integrity of suction
hose and connections
c.
Lance in low pressure mode – check and adjust
d.
Nozzle is badly worn – check and replace
a.
Worn oil seals – contact service centre
a.
Water supply low – check adequacy of water supply. Ensure suction filter
is below water level.
b.
Ingress of air into suction line – check integrity of suction hose
and connections
c.
Contact service centre
a.
Pump sucking in air – ensure all seals are firm, check integrity of suction
hose and connections
b.
Excessive temperature of liquid in pump – reduce temp to below 60 degrees
c.
Worn bearing or valves – contact service centre
a.
Worn out oil seals – contact service centre
a.
Worn piston seals – contact service centre
6
Maintenance
Before Each Use
12 month inspections
•
Inspect / top up oil levels in pump, gearbox, engine
•
Clean brass weight water inlet filter
•
Inspect high pressure hose and its connection for tightness and damage
•
Inspect suction hose and its connection for tightness and damage
•
High pressure jet must be inspects and changed if damaged
•
Overall system if there is any physical damage
•
Change the oil in Gearbox, Engine and high pressure pump
•
Inspect Gearbox and replace if damaged
•
Change high pressure jet
•
Change air filter
HIGHLINE
™
16
W: www.streamline.systems E: [email protected] T: +44 (0)1626 830 830
W: www.streamline.systems E: [email protected] T: +44 (0)1626 830 830
17