Temporarily remove the small white tube on inlet connection of the RO housing filter housing(See Fig 

2), and turn the water supply on, allowing the water to flush through the first three vertical filters for 

2-3 minutes, until all visible impurities have disappeared. Turn the water supply off.  

Identify  the  small  RO  plug  which  is  packaged  in  the  RO 

membrane bag. VERY IMPORTANT - Insert this plug into the 

notched side of the centre white tube of 

the membrane. (See Fig 3)  Remove the 

white  cap  on  the  right  hand  side  of  the 

horizontal RO housing and insert the blue RO 

membrane  with  the  large  black  rubber  seal  towards  the 

open end of the housing. (Fig 4) Screw the end cap of the 

membrane housing in place and refit the inlet tube. 

Turn the water supply on, and test the system for 

leaks. (Allow the system to run for approx. 15 – 20 

minutes for the TDS reading to drop to a realistic 

figure.)  

 

 

MAINTENANCE 

Replace the three vertical pre filters every 3 months, or sooner in very hard water areas. () 

OPTIONAL EXTRAS 

 

Pre R.O. Softening Filter, for use in hard water areas to bring TDS readings down and enhance 

R.O. Membrane life. (Part No. FH1K plus fittings) 

 

Male Hozelock type fittings kit. (Part No. KIT01300 brass fittings kit or KIT01301 nylon fittings 

kit) 

 

Post RO resin filter to produce 000ppm from the 300GPD system. (Part No. FH1D plus fittings) 

 

 

 