Remedying faults PP 1207
page 40 – April 2005
Adjusting low pressure: For
the low pressure
adjustment, the high
pressure control valve
(
DBV
) must be screwed out
so far that it no longer builds
up pressure.
Then drive the press plate
by manual operation into the
lower home position. When
the cylinder is in the home
position, the "low pressure"
pressure is built up in the
system and it can be read
off at the manometer.
The pressure can now be
regulated via the pressure
sequence valve
(DFV)
. The
pressure must not exceed
60 bar!
DFV
DBV
60 bar low pressure
Slacken counternuts and
depressurise DBV
.
Set DFV to the correct low pressure level.
7.2 Machine running very slowly and does high pressure in the normal range
1.
Pressure sequence valve or low-pressure pump both faulty