56
A P P L I C A T I O N A N D O P E R A T I O N
E N
6.4
Function of the buttons
Fig. 16
Buttons
6.5
Reference run
After switching on, a reference run must be car-
ried out to determine the mechanical zero points.
Operation button [A] flashes.
To start the reference run:
▷
Briefly press operation button [A].
The reference run is started. Operation button
[A] lights up.
The reference run can be stopped:
▷
Briefly press operation button [A].
The reference run is stopped. Operation button
[A] flashes.
To continue the reference run:
▷
Briefly press operation button [A].
The reference run is continued at the position
where it was stopped. Operation button [A]
lights up.
On completion of the reference run, the machine
returns to the starting position. Operation button
[A] goes out.
6.6
Program execution
Before executing a program, it must first be
loaded (see CAM software).
▷
Briefly press operation button [A].
The program is started. Operation button [A]
lights up.
The program can be stopped:
▷
Briefly press operation button [A] or service
button [B].
-or-
▷
Open the door.
The program is interrupted. Operation button
[A] flashes.
Key
Door shut
Door open
Operation
button [A]
Starts or stops the
reference run;
starts or stops the
current program;
activates or deac-
tivates the control
position; activates
the change posi-
tion for the blank
holder
Activates or
deactivates
the extrac-
tion system
Service
button [B]
Interrupts the cur-
rent program; acti-
vates the service
position; activates
the tool-changing
position; starts a
cleaning run of the
inspection window
Activates or
deactivates
the sealing
air
Tab. 2
Instead of with the buttons, these func-
tions can also be actuated via the software
(see instructions of the milling machine
software).
A