This chapter describes how to locate, install, remove, or replace a U916 T1/E1 PCI 
card in a Continuum Series 400-CO system. It contains the following sections:

‘‘Locating the PCI Card Slots”

‘‘Installing a U916 PCI Card”

‘‘Connecting the Cable”

‘‘Removing a U916 PCI Card”

Содержание U916 E1

Страница 1: ...Part Number R761 02 January 2005 U916 T1 E1 PCI Card Installation Guide...

Страница 2: ......

Страница 3: ...Stratus Technologies R761 02 U916 T1 E1 PCI Card Installation Guide...

Страница 4: ...ts are reserved No part of this document may be copied reproduced or translated either mechanically or electronically without the prior written consent of Stratus Technologies Stratus the Stratus logo...

Страница 5: ...ts 2 2 Installing a U916 PCI Card 2 4 Connecting the Cable 2 9 Removing a U916 PCI Card 2 12 3 Netra Sunfire Systems U916 PCI Card Installation 3 1 Netra System Locating the PCI Card Slots 3 1 SunFire...

Страница 6: ...e A 1 Telecommunications FCC Part 68 A 1 FCC Regulatory Compliance Notices A 1 Canadian Compliance A 3 Emissions A 3 Safety CSA 22 2 CB Scheme A 3 Telecommunications IC CS03 A 3 IC Regulatory Complian...

Страница 7: ...gure 2 9 Removing a U916 PCI Card Steps 4 and 5 2 13 Figure 2 10 Removing a U916 PCI Card Steps 7 and 8 2 14 Figure 2 11 Removing a U916 PCI Card Step 10 2 15 Figure 3 1 Netra 20 T4 System Available P...

Страница 8: ......

Страница 9: ...Tables ix Tables Table 3 1 Netra 20 T4 System PCI Slot Numbering 3 1 Table 3 2 SunFire V480 System PCI Slot Numbering 3 2 Table 4 1 PCI Card Cage Status Lights 4 3 Table 4 2 PCI Card LED Messages 4 4...

Страница 10: ......

Страница 11: ...nFire V480 series systems Audience This guide is intended for Stratus customers who are installing or maintaining a U916 T1 E1 PCI card in a Continuum Series 400 CO system or a supported Sun platform...

Страница 12: ...0 CO system Chapter 3 How to locate install and replace a U916 PCI card in a Netra 20 T4 or SunFire V480 system Chapter 4 How to get help and how to interpret U916 PCI card status lights Appendix A Th...

Страница 13: ...025H Netra T4 AC100 DC100 Installation and User s Guide 806 7334 11 Netra T4 AC100 DC100 Service and System Reference Manual 806 7336 10 Netra T4 AC100 DC100 Release Notes 816 1307 13 SunFire V480 Ser...

Страница 14: ...services your area If you cannot reach the center that services your area contact the CAC in the United States The table below lists the CAC telephone numbers all of which are available 24 x 7 For the...

Страница 15: ...an international telephone number within the same country you must replace the country code with the necessary prefix For example within the United States callers dial 1 800 221 6588 The telephone num...

Страница 16: ...About This Guide xvi U916 T1 E1 PCI Card Installation Guide R761...

Страница 17: ...tandard defines a 2 048 Mbps transfer rate in Europe The U916 PCI card uses a 32 bit PCI bus architecture that optimizes data flow between the system and the network resulting in the highest possible...

Страница 18: ...nstalled and configured at your site The Continuum Series 400 CO system can support up to eight U916 PCI cards four in each card cage 32 total ports while a Netra 20 T4 or SunFire V480 series system c...

Страница 19: ...rds are extremely sensitive to electrostatic discharge To avoid damaging a PCI card during handling take the following precautions C A U T I O N Do not walk around carrying a PCI card that is not in i...

Страница 20: ...Strap Jacks Cabling Specifications Due to the large variation in length requirements Stratus does not supply adapter cables to connect a U916 PCI card to the T1 E1 or PRI ISDN network The U916 PCI car...

Страница 21: ...card port and a CSU DSU Figure 1 4 N O T E S 1 The maximum length of the cable is 655 feet approximately 200 meters without a repeater 2 All configured ports not in use should be terminated with a loo...

Страница 22: ...rdware Components To maintain FCC emission compliance a ferrite bead see Figure 1 5 MUST be installed around the interface cables that run from the PCI card to the network See Connecting the Cable in...

Страница 23: ...ite Products Corporation http www fair rite com part number 0431173551 For additional 1 cable ferrite beads contact Dexter Magnetic Technologies Incorporated http www dextermag com part number F5 NF 8...

Страница 24: ...nection to an E1 circuit that requires a 75 ohm BNC termination a G 703 75 to120 ohm adapter Stratus Part Number B333 Software Requirements Before you can install a U916 PCI card the following softwar...

Страница 25: ...PCI Card Installation2 This chapter describes how to locate install remove or replace a U916 T1 E1 PCI card in a Continuum Series 400 CO system It contains the following sections Locating the PCI Car...

Страница 26: ...I Card Installation Guide R761 Locating the PCI Card Slots The PCI cards in a Continuum Series 400 CO system are installed in one of two PCI card cages which are located in the rear of the cabinet Fig...

Страница 27: ...s Continuum Systems U916 PCI Card Installation 2 3 Figure 2 2 shows the location of the PCI cards in the PCI card cages The U916 PCI card can be installed in any of the optional PCI card slots Figure...

Страница 28: ...CO system perform the following steps As you perform each step refer to the associated figure Before you can install and configure a U916 PCI card the appropriate communications hardware and software...

Страница 29: ...5 Figure 2 3 Installing a U916 PCI Card Step 1 2 Identify the slot into which you intend to install the PCI card 3 Loosen the thumbscrews and open the retainer bar that secures the filler panel to the...

Страница 30: ...ep 3 4 Touch the side of the PCI card cage to discharge any static electricity C A U T I O N To avoid damaging the PCI card leave the card in its static protective envelope until you are ready to inst...

Страница 31: ...and with the backplane connector see Figure 2 5 C A U T I O N To avoid snapping the voltage regulator position your hand and thumb above that component as you install the card 7 Press the U916 PCI car...

Страница 32: ...Installing a U916 PCI Card 2 8 U916 T1 E1 PCI Card Installation Guide R761 Figure 2 5 Installing a U916 PCI Card Steps 6 8...

Страница 33: ...onnector through the opening at the top of the cabinet Once the cable is installed adjust the latch to secure the cable to the card see Figure 2 8 C A U T I O N Make sure the U916 PCI card cable does...

Страница 34: ...All configured ports not in use should be terminated with a loopback plug to avoid performance degradation Performance degradation does not occur on an unconfigured port Loopback plugs are not supplie...

Страница 35: ...rd cage are illuminated indicating that the card is running correctly see Figure 2 8 and Chapter 4 Troubleshooting If this is a first time installation you must configure the software for the card For...

Страница 36: ...e that are using the U916 PCI card and all other cards in the associated card cage Opening the card cage will remove all power in that card cage from the network 3 Disable the PCI card Refer to the HP...

Страница 37: ...CI Card Steps 4 and 5 6 Identify the slot from which you intend to remove the PCI card N O T E Due to the heat generated when the system is running a PCI card may feel warm when you remove it The PCI...

Страница 38: ...2 14 U916 T1 E1 PCI Card Installation Guide R761 7 Loosen the thumbscrews and open the retainer bar that secures the card to the frame of the PCI card cage see Figure 2 10 Figure 2 10 Removing a U916...

Страница 39: ...r not to touch the components on the card especially the voltage regulator Pull one end of the card outward to loosen it from the backplane connector and then pull the other end outward to remove the...

Страница 40: ...the PCI card to the card cage frame and tighten the thumbscrews see Figure 2 11 If you are replacing the PCI card with a new card see the Installing a U916 PCI Card section in this chapter now If not...

Страница 41: ...ra System Locating the PCI Card Slots The PCI cards in a Netra 20 T4 series system are installed in one of three available PCI card slots accessed from the top of the cabinet see Figure 3 1 The PCI ca...

Страница 42: ...Figure 3 2 and Figure 3 3 The other three slots are half length and cannot accommodate a U916 PCI card Note that PCI 0 and PCI 1 are to the left of the existing RSC card while PCI 2 is to the right Ta...

Страница 43: ...em Locating the PCI Card Slots Netra Sunfire Systems U916 PCI Card Installation 3 3 Figure 3 2 SunFire V480 System Available PCI Slots front view A Figure 3 3 SunFire V480 System Available PCI Slots f...

Страница 44: ...install the PCI card s as described in Netra System Locating the PCI Card Slots earlier in this chapter 4 Touch the side of the chassis to discharge any static electricity see your Netra 20 T4 series...

Страница 45: ...5 Netra 20 T4 System Installing PCI Slot 3 rear view 7 Press the U916 PCI card gently but firmly into the PCI connector 8 Install and tighten the PCI card retaining screw so that cable insertion or re...

Страница 46: ...I card in a SunFire V480 series system perform the following steps As you perform each step refer to the associated figure 1 Shut down enter init 0 and power off the system 2 Remove the cover from the...

Страница 47: ...e 3 6 for a Netra 20 T4 example 9 Install the chassis cover This can be done either before or after installing the cables 10 Power on the system and connect the cables see Connecting the Cable The cab...

Страница 48: ...cable near the connector The ferrite bead can hold up to 4 cables and is provided with the U916 PCI card see Cabling Specifications in Chapter 1 for information about getting additional 4 cable ferri...

Страница 49: ...d in Europe at 31 36 546 1070 Radisys Part Number 87H3588 ARTIC 1000 2000 1 Port RJ 48 Plug Loopback plugs may also be constructed using a standard RJ 48 plug with a jumper from pin one to pin four an...

Страница 50: ...ots or SunFire System Locating the PCI Card Slots earlier in this chapter N O T E Due to the heat generated when the system is running a PCI card may feel warm when you remove it The PCI card will coo...

Страница 51: ...Card Netra Sunfire Systems U916 PCI Card Installation 3 11 10 Install the access cover 11 Power on and boot the system N O T E See the SINAP SS7 Quick Start Guide R8070 or the SINAP SS7 Installation...

Страница 52: ...Removing or Replacing a U916 PCI Card 3 12 U916 T1 E1 PCI Card Installation Guide R761...

Страница 53: ...tions in the online system error log files and displays corresponding error messages on the system console Solaris error log files use the following path name var adm messages Getting Help Stratus sys...

Страница 54: ...ontacted you notify the CAC of the card failure The CAC will verify your diagnosis NOTE By helping you perform online diagnostic tests the CAC might be able to assist you in fixing a PCI card related...

Страница 55: ...low Green On Off Off 1 The PCI card has failed or has been disabled by the user or 2 The light is temporarily illuminated when the card is being initialized 1 Do not remove the card from service witho...

Страница 56: ...e 4 2 shows the status light on the U916 PCI card and Table 4 2 explains its meaning Figure 4 2 Status Light on the U916 PCI Card Table 4 2 PCI Card LED Messages Light Meaning Green Indicates the card...

Страница 57: ...and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in...

Страница 58: ...ions Commission If they do you will be notified in advance to give you an opportunity to maintain uninterrupted telephone service Do not attempt to repair or modify this equipment If defective return...

Страница 59: ...le Reglement sur le brouillage radioelectrique edicte par le Ministere des Communications du Canada Notice The Industry Canada label identifies certified equipment This certification means that the eq...

Страница 60: ...oop which is used by the device to prevent overloading The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all the...

Страница 61: ...International Compliance Summary Compliance A 5...

Страница 62: ...International Compliance Summary A 6 U916 T1 E1 PCI Card Installation Guide R761...

Страница 63: ...International Compliance Summary Compliance A 7...

Страница 64: ...International Compliance Summary A 8 U916 T1 E1 PCI Card Installation Guide R761...

Страница 65: ...International Compliance Summary Compliance A 9...

Страница 66: ...International Compliance Summary A 10 U916 T1 E1 PCI Card Installation Guide R761...

Страница 67: ...International Compliance Summary Compliance A 11...

Страница 68: ...International Compliance Summary A 12 U916 T1 E1 PCI Card Installation Guide R761...

Страница 69: ...International Compliance Summary Compliance A 13...

Страница 70: ...International Compliance Summary A 14 U916 T1 E1 PCI Card Installation Guide R761...

Страница 71: ...International Compliance Summary Compliance A 15...

Страница 72: ...International Compliance Summary A 16 U916 T1 E1 PCI Card Installation Guide R761...

Страница 73: ...toring power to PCI card cage 2 10 2 16 suspending power to PCI card cage 2 4 2 12 documentation accessing xiii notation conventions xii related xii revision information xi E E1 standard 1 1 electrost...

Страница 74: ...ble to SunFire 3 8 handling 1 3 installing DNCP 2 4 installing Netra 3 4 installing SunFire 3 6 notifying CAC when problem 4 2 preventing ESD when handling 1 3 removing DNCP 2 12 removing Netra 3 10 r...

Страница 75: ...cable to Netra 3 8 connecting cable to SunFire 3 8 description of 1 1 hardware requirements 1 8 installing DNCP 2 4 installing Netra 3 4 installing SunFire 3 6 meaning of status light 4 4 removing DN...

Страница 76: ...Index Index 4 U916 T1 E1 PCI Card Installation Guide R761...