background image

3

equipped with a power supply cord having a grounding wire with an appropriate ground-

ing plug. The plug must be plugged into an outlet that is properly installed and grounded 

in accordance with all local codes and ordinances.
Check with a qualified electrician or serviceman if the grounding instructions are 

not completely understood, or if you are not sure whether the product is properly 

grounded. Do not modify the plug provided. If it will not fit the outlet, have the 

proper outlet installed by a qualified electrician.
Model that is permanently wired:
 This compressor must be connected to a grounded, 

metallic, permanent wiring system, or an equipment grounding terminal or lead on the 

compressor.
Power supply wiring must conform to all required safety codes and be installed by a 

qualified person. Check that all supply voltage agrees with that listed on compressor 

name plate.
Extension Cords: Use only a 3-wire extension cord that has a 3-blade grounding plug. 

Connect extension cord plug to a matching 3-slot receptacle. Do not use an adapter. 

Make sure your extension cord is in good condition. Check that the gage wire of the ex-

tension cord is the correct size wire to carry the current this compressor will draw.
Do not exceed 100' with minimum 12 gage wire (only up to 10 amps) for extension cords.
An undersized cord is a potential fire hazard and will cause a drop in line voltage resulting 

in loss of power, causing compressor to overheat. If in doubt, use the next heavier gage 

cord. The smaller the gage number, the heavier the wire gage.

OPERATION:

 

WARNING! Injury Hazard. Install proper safety guards as needed. Keep fingers 

and objects away from openings and rotating parts. When provided, motor termi-

nal covers must be in place for safe operation. Product surfaces become very hot during 

operation, allow surfaces to cool before handling. Air stream from product may contain 

solid or liquid material that can result in eye or skin damage, wear proper eye protection. 

Wear hearing protection. Failure to follow these instructions can result in burns, eye injury, 

or other serious injury.
It is your responsibility to operate this compressor at recommended pressures or vacuum 

duties and room ambient temperatures.
 START  UP:  If motor fails to start or slows down significantly under load, shut off and 

disconnect from power supply. Check that the supply voltage is correct and verify motor 

is turning in the proper direction. Check plug, cord and switch for damage. If the thermal 

protection switch has tripped, the motor can restart after cooling.

MAINTENANCE:

 

WARNING! Electrical Shock Hazard. Disconnect electrical power supply 

before performing maintenance. Failure to follow these instructions can 

result in death, fire, or electrical shock.

 

WARNING! Injury Hazard. Product surfaces become very hot during operation, 

allow surfaces to cool before handling. Air stream from product may contain solid 

or liquid material that can result in eye or skin damage, wear proper eye protection. Wear 

hearing protection. Failure to follow these instructions can result in burns, eye injury, or 

other serious injury.

Содержание SRC25

Страница 1: ...s exhaust air can become very hot Corrosive gases and particulate material will damage unit water vapor oil based contaminants or other liquids must be ltered out Product performance changes when usin...

Страница 2: ...flow through pump MOTOR CONTROL It is your responsibility to contact a qualified electrician and assure that the electri cal installation is adequate and in conformance with all national and local cod...

Страница 3: ...at If in doubt use the next heavier gage cord The smaller the gage number the heavier the wire gage OPERATION WARNING Injury Hazard Install proper safety guards as needed Keep fingers and objects away...

Страница 4: ...ed of ferrous metals or aluminum which are subject to rust and corrosion when pumping considerable vapors such as water Follow the steps below to assure correct storage and shutdown between operating...

Страница 5: ...he valve plate s with ports is correct and place over cylinders 11 Remove old and install new head o rings in the o ring grooves on top of valve plate 12 Reinstall head over valve plate s checking tha...

Страница 6: ...nd Belt Cap 12 Cylinder O ring 13 Screw 14 Fan Clockwise 15 Pipe Plug 16 Filter 18 Valve Plate 19 Leaf Valve 20 Valve Limiter 21 Valve Screw 22 Valve Screw 23 Valve Retainer 25 Bearing 26 Cup 27 Retai...

Страница 7: ...et Screw 10 Fan 11 Pipe Plug 13 Valve Plate 14 Leaf Valve 15 Valve Limiter 16 Valve Screw 17 Leaf Valve 18 Valve Screw 19 Valve Retainer 20 Plug 22 Bearing 23 Cup 24 Retainer Plate 25 Eccentric 26 Rod...

Страница 8: ...crews cylinder O ring s head O ring s and inspect valves and valve retainers If leaf valves need to be replaced a complete leaf valve plate is included step 12 The screws holding the leaf valves are s...

Страница 9: ...Retainer 7 Leaf Valve 8 Valve Plate 9 Tube O Ring 10 Valve Screw 11 Cylinder O Ring 12 Cylinder 13 Retainer Screw 14 Retainer Plate 15 Piston Cup 16 Rod Assembly 17 Shroud 18 Fan 19 Shroud Screw 20 Va...

Страница 10: ...e sure to include RMA number original receipt name return address and phone number in package In the event of a warranty claim please return the product postage prepaid with the origi nal receipt for...

Страница 11: ...11 Model Serial Please keep a copy for your records 10 digit number by barcode on compressor unit MAINTENANCE NOTES...

Страница 12: ...800 448 3873 Grant Michigan www easypropondproducts com info easypropondproducts com 9984 5 17...