background image

Safety

Conventions used in this Guide

Page 3

© Copyright 2020 Stratasys. All rights reserved.

Safety

Conventions used in this Guide

Below are safety-related symbols used on the extraction system and referred to within this 

manual.

Electrical Safety

The air extraction system has been designed to meet the safety requirements of the Essential 

Health and Safety Requirements of the Machinery Directive 2006/42/EC.
Disconnect the power from the system before opening the cover.
To reduce the risk of fire, electric shock, or injury:
1. Always disconnect the system from the main power supply before servicing.
2. Use this system only as described in this manual.
3. Connect the system to a properly grounded outlet.

Warning/Danger:

Refers dangerous situations which will result in death or severe injury. Refer to this 

guide before proceeding when this symbol is displayed on the system.

Caution:

Refers to a possibly harmful situation. If not avoided, damage could be caused to the 

system or its environment. Refer to this guide before proceeding when this symbol is 

displayed on the system.

Important:

Refers to tips and other particularly useful information. This does not indicate a 

dangerous or harmful situation.

Содержание ProAero

Страница 1: ...DOC 01003 Rev D ProAero Air Extraction System Installation and User Manual...

Страница 2: ...or consequential damages in connection with the furnishing performance or use of this material Stratasys makes no warranty of any kind with regard to this material including but not limited to the imp...

Страница 3: ...ion and Skin 4 Filter Selection 4 Warning and Information Labels 5 Preparation 5 Installation 7 Connecting to the Power Supply 7 Connecting to the 3D Printer 7 Operation 8 Setting the Desired Airflow...

Страница 4: ...1 Copyright 2020 Stratasys All rights reserved Overview Figure 1 Air extraction system front Figure 2 Control panel Cover Indicators and controls Cover clip Air inlet Filter change indicator Motor spe...

Страница 5: ...ser s needs The rear outlet can be covered using the plate screwed to the underside of the extraction system The air then exits through the opening under the system When the rear outlet is in use cove...

Страница 6: ...electric shock or injury 1 Always disconnect the system from the mainpower supply before servicing 2 Use this system only as described in this manual 3 Connect the system to a properly grounded outle...

Страница 7: ...agitates and releases some of these particulates to the surroundings enabling them to enter the respiratory system and eyes of the operator Additionally depending on the materials used the particulat...

Страница 8: ...nt to the label Bottom panel Electrical hazard Removal of panels with this label exposes electrical components Bottom panel Warning Turn the power to the system off before opening the panel with this...

Страница 9: ...ll rights reserved 2 Verify that the filter is positioned correctly before replacing the cover and securing the clips Figure 4 Securing the cover Caution Do not cover the exhaust outlets as this restr...

Страница 10: ...azard Connecting to the 3D Printer 1 Connect the control cable from the extraction system shown in Figure 3 page 2 to the AUX 24V connector in the connection panel on the back of the J55 Figure 5 J55...

Страница 11: ...the motor speed to maintain the correct flow rate and compensate for any loss in performance To adjust the airflow Press to increase airflow and press to decrease airflow The level of airflow is indi...

Страница 12: ...ion system contains a pre filter pad and a combined filter Replace the filters regularly To maintain performance it is important that the filters are replaced with identical replacement filters To re...

Страница 13: ...ever comes first Combined filter every 350 printing hours or 6 months or sooner if the filter replacement indicator turns red and flashes Figure 7 Filter replacement indicator on control panel To repl...

Страница 14: ...8 Filter elements To replace the combined filter 1 Turn off the system power switch 2 Open the clips on the sides of the system andremove the cover 3 Lift the filter out of the system Do not activate...

Страница 15: ...he customer s responsibility to verify that the disposal of filters complies with all local and or industrial regulations System Specifications Capacity 75 m h 44CFM Weight 10 5 kg 23 1 lbs Fan type C...

Страница 16: ...3 Copyright 2020 Stratasys All rights reserved Filter Information Filter Type Construction Efficiency Pre Filter Pad Glass Fiber F7 96 2 microns Combined Filter HEPA Maxipleat Construction with Webbin...

Страница 17: ...THE 3D PRINTING SOLUTIONS COMPANY www stratasys com _____ c support stratasys com Copyright 2020 Stratasys Ltd All rights reserved DOC 01003 Rev D...

Отзывы: