To test and calibrate UV lamp radiation:
1. Start the UV Calibration Wizard from the
Options
menu.
2. In the following screen, select
Calibrate UV Intensity
to adjust the lamp’s
radiation level to the acceptable range.
Figure 4-105 UV Test/Calibration selection
3. In the following screen, select the UV sensor and measuring device to be
used.
Figure 4-106 UV device selection
UV Measuring Device
When you use the Stratasys UV sensor box (TOL-03005-S), you connect it to
the printer. The wizard automatically measures and calibrates the UV
radiation.
If you use a stand-alone UV radiation meter, you need to manually enter the
readings from the meter in the wizard screens.